Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders

The report describes a method for a fast and precise beam energy measurement in the beam energy range 0.5-2 GeV and its application at various e+e- colliders. Low-energy laser photons interact head-on with the electron or positron beam and produce Compton backscattered photons whose energy is precis...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaminskiy, V V, Achasov, M N, Muchnoi, N Yu, Zhilich, V N
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.23727/CERN-Proceedings-2017-001.119
http://cds.cern.ch/record/2302006
_version_ 1780957269961211904
author Kaminskiy, V V
Achasov, M N
Muchnoi, N Yu
Zhilich, V N
author_facet Kaminskiy, V V
Achasov, M N
Muchnoi, N Yu
Zhilich, V N
author_sort Kaminskiy, V V
collection CERN
description The report describes a method for a fast and precise beam energy measurement in the beam energy range 0.5-2 GeV and its application at various e+e- colliders. Low-energy laser photons interact head-on with the electron or positron beam and produce Compton backscattered photons whose energy is precisely measured by HPGe detector. The method allows measuring the beam energy with relative accuracy of ∼2-5.10-5. The method was successfully applied at VEPP-4M, VEPP-3, VEPP-2000 (BINP, Russia) and BEPC-II (IHEP, China).
id oai-inspirehep.net-1650330
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16503302019-09-30T06:29:59Zdoi:10.23727/CERN-Proceedings-2017-001.119http://cds.cern.ch/record/2302006engKaminskiy, V VAchasov, M NMuchnoi, N YuZhilich, V NFast and Precise Beam Energy Measurement using Compton Backscattering at e+e- CollidersDetectors and Experimental TechniquesThe report describes a method for a fast and precise beam energy measurement in the beam energy range 0.5-2 GeV and its application at various e+e- colliders. Low-energy laser photons interact head-on with the electron or positron beam and produce Compton backscattered photons whose energy is precisely measured by HPGe detector. The method allows measuring the beam energy with relative accuracy of ∼2-5.10-5. The method was successfully applied at VEPP-4M, VEPP-3, VEPP-2000 (BINP, Russia) and BEPC-II (IHEP, China).oai:inspirehep.net:16503302017
spellingShingle Detectors and Experimental Techniques
Kaminskiy, V V
Achasov, M N
Muchnoi, N Yu
Zhilich, V N
Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title_full Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title_fullStr Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title_full_unstemmed Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title_short Fast and Precise Beam Energy Measurement using Compton Backscattering at e+e- Colliders
title_sort fast and precise beam energy measurement using compton backscattering at e+e- colliders
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.23727/CERN-Proceedings-2017-001.119
http://cds.cern.ch/record/2302006
work_keys_str_mv AT kaminskiyvv fastandprecisebeamenergymeasurementusingcomptonbackscatteringateecolliders
AT achasovmn fastandprecisebeamenergymeasurementusingcomptonbackscatteringateecolliders
AT muchnoinyu fastandprecisebeamenergymeasurementusingcomptonbackscatteringateecolliders
AT zhilichvn fastandprecisebeamenergymeasurementusingcomptonbackscatteringateecolliders