Cargando…

Electrical insulation testing for ITER fusion tokamak

The uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Gaxiola, E, Evans, D, Laquiere, J, Laurenti, A, Libeyre, P, Lyraud, C, Piccin, R, Rinaudo, G, Simon, F, Vollmann, T, Martovetsky, N, Niu, E, Langeslag, S, Sgobba, S, Khumthong, K, Norausky, N, Smith, J, Wei, J, Wu, H, Yu, X
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1109/EIC.2017.8004670
http://cds.cern.ch/record/2303655
_version_ 1780957467269660672
author Gaxiola, E
Evans, D
Laquiere, J
Laurenti, A
Libeyre, P
Lyraud, C
Piccin, R
Rinaudo, G
Simon, F
Vollmann, T
Martovetsky, N
Niu, E
Langeslag, S
Sgobba, S
Khumthong, K
Norausky, N
Smith, J
Wei, J
Wu, H
Yu, X
author_facet Gaxiola, E
Evans, D
Laquiere, J
Laurenti, A
Libeyre, P
Lyraud, C
Piccin, R
Rinaudo, G
Simon, F
Vollmann, T
Martovetsky, N
Niu, E
Langeslag, S
Sgobba, S
Khumthong, K
Norausky, N
Smith, J
Wei, J
Wu, H
Yu, X
author_sort Gaxiola, E
collection CERN
description The uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operations of the magnet coil winding pack (WP) vacuum pressure insulation (VPI) beam qualification, followed in 2016 by start of magnets series production in the USA and China [1, 2]. Useful to be considered common state-of-the-art electrical power components testing practices [3, 4] are presented here as performed to verify that the integrity and insulation of the various components are within acceptable limits during different phases of the fabrication and to certify acceptance on delivery of the complete coils. Initial measurement plans were complemented into electrical tests with typical high voltage engineering implemented measures as a pre-requisite to successfully validate produced results. The above permitted the first quantitative validation of the obtained final production, including life time behavior.
id oai-inspirehep.net-1650749
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16507492019-09-30T06:29:59Zdoi:10.1109/EIC.2017.8004670http://cds.cern.ch/record/2303655engGaxiola, EEvans, DLaquiere, JLaurenti, ALibeyre, PLyraud, CPiccin, RRinaudo, GSimon, FVollmann, TMartovetsky, NNiu, ELangeslag, SSgobba, SKhumthong, KNorausky, NSmith, JWei, JWu, HYu, XElectrical insulation testing for ITER fusion tokamakEngineeringThe uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operations of the magnet coil winding pack (WP) vacuum pressure insulation (VPI) beam qualification, followed in 2016 by start of magnets series production in the USA and China [1, 2]. Useful to be considered common state-of-the-art electrical power components testing practices [3, 4] are presented here as performed to verify that the integrity and insulation of the various components are within acceptable limits during different phases of the fabrication and to certify acceptance on delivery of the complete coils. Initial measurement plans were complemented into electrical tests with typical high voltage engineering implemented measures as a pre-requisite to successfully validate produced results. The above permitted the first quantitative validation of the obtained final production, including life time behavior.oai:inspirehep.net:16507492017
spellingShingle Engineering
Gaxiola, E
Evans, D
Laquiere, J
Laurenti, A
Libeyre, P
Lyraud, C
Piccin, R
Rinaudo, G
Simon, F
Vollmann, T
Martovetsky, N
Niu, E
Langeslag, S
Sgobba, S
Khumthong, K
Norausky, N
Smith, J
Wei, J
Wu, H
Yu, X
Electrical insulation testing for ITER fusion tokamak
title Electrical insulation testing for ITER fusion tokamak
title_full Electrical insulation testing for ITER fusion tokamak
title_fullStr Electrical insulation testing for ITER fusion tokamak
title_full_unstemmed Electrical insulation testing for ITER fusion tokamak
title_short Electrical insulation testing for ITER fusion tokamak
title_sort electrical insulation testing for iter fusion tokamak
topic Engineering
url https://dx.doi.org/10.1109/EIC.2017.8004670
http://cds.cern.ch/record/2303655
work_keys_str_mv AT gaxiolae electricalinsulationtestingforiterfusiontokamak
AT evansd electricalinsulationtestingforiterfusiontokamak
AT laquierej electricalinsulationtestingforiterfusiontokamak
AT laurentia electricalinsulationtestingforiterfusiontokamak
AT libeyrep electricalinsulationtestingforiterfusiontokamak
AT lyraudc electricalinsulationtestingforiterfusiontokamak
AT piccinr electricalinsulationtestingforiterfusiontokamak
AT rinaudog electricalinsulationtestingforiterfusiontokamak
AT simonf electricalinsulationtestingforiterfusiontokamak
AT vollmannt electricalinsulationtestingforiterfusiontokamak
AT martovetskyn electricalinsulationtestingforiterfusiontokamak
AT niue electricalinsulationtestingforiterfusiontokamak
AT langeslags electricalinsulationtestingforiterfusiontokamak
AT sgobbas electricalinsulationtestingforiterfusiontokamak
AT khumthongk electricalinsulationtestingforiterfusiontokamak
AT norauskyn electricalinsulationtestingforiterfusiontokamak
AT smithj electricalinsulationtestingforiterfusiontokamak
AT weij electricalinsulationtestingforiterfusiontokamak
AT wuh electricalinsulationtestingforiterfusiontokamak
AT yux electricalinsulationtestingforiterfusiontokamak