The uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operatio...
Autores principales: | , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2017
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/EIC.2017.8004670 http://cds.cern.ch/record/2303655 |
_version_ | 1780957467269660672 |
---|---|
author | Gaxiola, E Evans, D Laquiere, J Laurenti, A Libeyre, P Lyraud, C Piccin, R Rinaudo, G Simon, F Vollmann, T Martovetsky, N Niu, E Langeslag, S Sgobba, S Khumthong, K Norausky, N Smith, J Wei, J Wu, H Yu, X |
author_facet | Gaxiola, E Evans, D Laquiere, J Laurenti, A Libeyre, P Lyraud, C Piccin, R Rinaudo, G Simon, F Vollmann, T Martovetsky, N Niu, E Langeslag, S Sgobba, S Khumthong, K Norausky, N Smith, J Wei, J Wu, H Yu, X |
author_sort | Gaxiola, E |
collection | CERN |
description | The uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operations of the magnet coil winding pack (WP) vacuum pressure insulation (VPI) beam qualification, followed in 2016 by start of magnets series production in the USA and China [1, 2]. Useful to be considered common state-of-the-art electrical power components testing practices [3, 4] are presented here as performed to verify that the integrity and insulation of the various components are within acceptable limits during different phases of the fabrication and to certify acceptance on delivery of the complete coils. Initial measurement plans were complemented into electrical tests with typical high voltage engineering implemented measures as a pre-requisite to successfully validate produced results. The above permitted the first quantitative validation of the obtained final production, including life time behavior. |
id | oai-inspirehep.net-1650749 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2017 |
record_format | invenio |
spelling | oai-inspirehep.net-16507492019-09-30T06:29:59Zdoi:10.1109/EIC.2017.8004670http://cds.cern.ch/record/2303655engGaxiola, EEvans, DLaquiere, JLaurenti, ALibeyre, PLyraud, CPiccin, RRinaudo, GSimon, FVollmann, TMartovetsky, NNiu, ELangeslag, SSgobba, SKhumthong, KNorausky, NSmith, JWei, JWu, HYu, XElectrical insulation testing for ITER fusion tokamakEngineeringThe uniqueness of the ITER fusion project drives purpose and scope here to fulfil (functional) Procurement Arrangement (PA) requirements for the Central Solenoid (CS) and Correction Coil (CC) magnets' electrical insulation [1-3]; as used and undertaken for covering high voltage testing operations of the magnet coil winding pack (WP) vacuum pressure insulation (VPI) beam qualification, followed in 2016 by start of magnets series production in the USA and China [1, 2]. Useful to be considered common state-of-the-art electrical power components testing practices [3, 4] are presented here as performed to verify that the integrity and insulation of the various components are within acceptable limits during different phases of the fabrication and to certify acceptance on delivery of the complete coils. Initial measurement plans were complemented into electrical tests with typical high voltage engineering implemented measures as a pre-requisite to successfully validate produced results. The above permitted the first quantitative validation of the obtained final production, including life time behavior.oai:inspirehep.net:16507492017 |
spellingShingle | Engineering Gaxiola, E Evans, D Laquiere, J Laurenti, A Libeyre, P Lyraud, C Piccin, R Rinaudo, G Simon, F Vollmann, T Martovetsky, N Niu, E Langeslag, S Sgobba, S Khumthong, K Norausky, N Smith, J Wei, J Wu, H Yu, X Electrical insulation testing for ITER fusion tokamak |
title | Electrical insulation testing for ITER fusion tokamak |
title_full | Electrical insulation testing for ITER fusion tokamak |
title_fullStr | Electrical insulation testing for ITER fusion tokamak |
title_full_unstemmed | Electrical insulation testing for ITER fusion tokamak |
title_short | Electrical insulation testing for ITER fusion tokamak |
title_sort | electrical insulation testing for iter fusion tokamak |
topic | Engineering |
url | https://dx.doi.org/10.1109/EIC.2017.8004670 http://cds.cern.ch/record/2303655 |
work_keys_str_mv | AT gaxiolae electricalinsulationtestingforiterfusiontokamak AT evansd electricalinsulationtestingforiterfusiontokamak AT laquierej electricalinsulationtestingforiterfusiontokamak AT laurentia electricalinsulationtestingforiterfusiontokamak AT libeyrep electricalinsulationtestingforiterfusiontokamak AT lyraudc electricalinsulationtestingforiterfusiontokamak AT piccinr electricalinsulationtestingforiterfusiontokamak AT rinaudog electricalinsulationtestingforiterfusiontokamak AT simonf electricalinsulationtestingforiterfusiontokamak AT vollmannt electricalinsulationtestingforiterfusiontokamak AT martovetskyn electricalinsulationtestingforiterfusiontokamak AT niue electricalinsulationtestingforiterfusiontokamak AT langeslags electricalinsulationtestingforiterfusiontokamak AT sgobbas electricalinsulationtestingforiterfusiontokamak AT khumthongk electricalinsulationtestingforiterfusiontokamak AT norauskyn electricalinsulationtestingforiterfusiontokamak AT smithj electricalinsulationtestingforiterfusiontokamak AT weij electricalinsulationtestingforiterfusiontokamak AT wuh electricalinsulationtestingforiterfusiontokamak AT yux electricalinsulationtestingforiterfusiontokamak |