Characterization of the mass-dependent transmission efficiency of a CIMS

Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way...

Descripción completa

Detalles Bibliográficos
Autores principales: Heinritzi, Martin, Simon, Mario, Steiner, Gerhard, Wagner, Andrea C, Kürten, Andreas, Hansel, Armin, Curtius, Joachim
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:https://dx.doi.org/10.5194/amt-9-1449-2016
http://cds.cern.ch/record/2310552
_version_ 1780957862182256640
author Heinritzi, Martin
Simon, Mario
Steiner, Gerhard
Wagner, Andrea C
Kürten, Andreas
Hansel, Armin
Curtius, Joachim
author_facet Heinritzi, Martin
Simon, Mario
Steiner, Gerhard
Wagner, Andrea C
Kürten, Andreas
Hansel, Armin
Curtius, Joachim
author_sort Heinritzi, Martin
collection CERN
description Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to self-consistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m∕z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m∕z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.
id oai-inspirehep.net-1663812
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-16638122019-09-30T06:29:59Zdoi:10.5194/amt-9-1449-2016http://cds.cern.ch/record/2310552engHeinritzi, MartinSimon, MarioSteiner, GerhardWagner, Andrea CKürten, AndreasHansel, ArminCurtius, JoachimCharacterization of the mass-dependent transmission efficiency of a CIMSNuclear Physics - ExperimentKnowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to self-consistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m∕z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m∕z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.oai:inspirehep.net:16638122016
spellingShingle Nuclear Physics - Experiment
Heinritzi, Martin
Simon, Mario
Steiner, Gerhard
Wagner, Andrea C
Kürten, Andreas
Hansel, Armin
Curtius, Joachim
Characterization of the mass-dependent transmission efficiency of a CIMS
title Characterization of the mass-dependent transmission efficiency of a CIMS
title_full Characterization of the mass-dependent transmission efficiency of a CIMS
title_fullStr Characterization of the mass-dependent transmission efficiency of a CIMS
title_full_unstemmed Characterization of the mass-dependent transmission efficiency of a CIMS
title_short Characterization of the mass-dependent transmission efficiency of a CIMS
title_sort characterization of the mass-dependent transmission efficiency of a cims
topic Nuclear Physics - Experiment
url https://dx.doi.org/10.5194/amt-9-1449-2016
http://cds.cern.ch/record/2310552
work_keys_str_mv AT heinritzimartin characterizationofthemassdependenttransmissionefficiencyofacims
AT simonmario characterizationofthemassdependenttransmissionefficiencyofacims
AT steinergerhard characterizationofthemassdependenttransmissionefficiencyofacims
AT wagnerandreac characterizationofthemassdependenttransmissionefficiencyofacims
AT kurtenandreas characterizationofthemassdependenttransmissionefficiencyofacims
AT hanselarmin characterizationofthemassdependenttransmissionefficiencyofacims
AT curtiusjoachim characterizationofthemassdependenttransmissionefficiencyofacims