Cargando…
A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations
Reliable and reproducible measurements of atmospheric aerosol particle number size distributions below 10 nm require optimized classification instruments with high particle transmission efficiency. Almost all differential mobility analyzers (DMAs) have an unfavorable potential gradient at the outlet...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5194/amt-9-2709-2016 http://cds.cern.ch/record/2310664 |
_version_ | 1780957862405603328 |
---|---|
author | Franchin, Alessandro Downard, Andy Kangasluoma, Juha Nieminen, Tuomo Lehtipalo, Katrianne Steiner, Gerhard Manninen, Hanna E Petäjä, Tuukka Flagan, Richard C Kulmala, Markku |
author_facet | Franchin, Alessandro Downard, Andy Kangasluoma, Juha Nieminen, Tuomo Lehtipalo, Katrianne Steiner, Gerhard Manninen, Hanna E Petäjä, Tuukka Flagan, Richard C Kulmala, Markku |
author_sort | Franchin, Alessandro |
collection | CERN |
description | Reliable and reproducible measurements of atmospheric aerosol particle number size distributions below 10 nm require optimized classification instruments with high particle transmission efficiency. Almost all differential mobility analyzers (DMAs) have an unfavorable potential gradient at the outlet (e.g., long column, Vienna type) or at the inlet (nano-radial DMA), preventing them from achieving a good transmission efficiency for the smallest nanoparticles. We developed a new high-transmission inlet for the Caltech nano-radial DMA (nRDMA) that increases the transmission efficiency to 12 % for ions as small as 1.3 nm in Millikan–Fuchs mobility equivalent diameter, Dp (corresponding to 1.2 × 10−4 m2 V−1 s−1 in electrical mobility). We successfully deployed the nRDMA, equipped with the new inlet, in chamber measurements, using a particle size magnifier (PSM) and as a booster a condensation particle counter (CPC). With this setup, we were able to measure size distributions of ions within a mobility range from 1.2 × 10−4 to 5.8 × 10−6 m2 V−1 s−1. The system was modeled, tested in the laboratory and used to measure negative ions at ambient concentrations in the CLOUD (Cosmics Leaving Outdoor Droplets) 7 measurement campaign at CERN. We achieved a higher size resolution (R = 5.5 at Dp = 1.47 nm) than techniques currently used in field measurements (e.g., Neutral cluster and Air Ion Spectrometer (NAIS), which has a R ∼ 2 at largest sizes, and R ∼ 1.8 at Dp = 1.5 nm) and maintained a good total transmission efficiency (6.3 % at Dp = 1.5 nm) at moderate inlet and sheath airflows (2.5 and 30 L min−1, respectively). In this paper, by measuring size distributions at high size resolution down to 1.3 nm, we extend the limit of the current technology. The current setup is limited to ion measurements. However, we envision that future research focused on the charging mechanisms could extend the technique to measure neutral aerosol particles as well, so that it will be possible to measure size distributions of ambient aerosols from 1 nm to 1 µm. |
id | oai-inspirehep.net-1663813 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2016 |
record_format | invenio |
spelling | oai-inspirehep.net-16638132019-09-30T06:29:59Zdoi:10.5194/amt-9-2709-2016http://cds.cern.ch/record/2310664engFranchin, AlessandroDownard, AndyKangasluoma, JuhaNieminen, TuomoLehtipalo, KatrianneSteiner, GerhardManninen, Hanna EPetäjä, TuukkaFlagan, Richard CKulmala, MarkkuA new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrationsNuclear Physics - ExperimentReliable and reproducible measurements of atmospheric aerosol particle number size distributions below 10 nm require optimized classification instruments with high particle transmission efficiency. Almost all differential mobility analyzers (DMAs) have an unfavorable potential gradient at the outlet (e.g., long column, Vienna type) or at the inlet (nano-radial DMA), preventing them from achieving a good transmission efficiency for the smallest nanoparticles. We developed a new high-transmission inlet for the Caltech nano-radial DMA (nRDMA) that increases the transmission efficiency to 12 % for ions as small as 1.3 nm in Millikan–Fuchs mobility equivalent diameter, Dp (corresponding to 1.2 × 10−4 m2 V−1 s−1 in electrical mobility). We successfully deployed the nRDMA, equipped with the new inlet, in chamber measurements, using a particle size magnifier (PSM) and as a booster a condensation particle counter (CPC). With this setup, we were able to measure size distributions of ions within a mobility range from 1.2 × 10−4 to 5.8 × 10−6 m2 V−1 s−1. The system was modeled, tested in the laboratory and used to measure negative ions at ambient concentrations in the CLOUD (Cosmics Leaving Outdoor Droplets) 7 measurement campaign at CERN. We achieved a higher size resolution (R = 5.5 at Dp = 1.47 nm) than techniques currently used in field measurements (e.g., Neutral cluster and Air Ion Spectrometer (NAIS), which has a R ∼ 2 at largest sizes, and R ∼ 1.8 at Dp = 1.5 nm) and maintained a good total transmission efficiency (6.3 % at Dp = 1.5 nm) at moderate inlet and sheath airflows (2.5 and 30 L min−1, respectively). In this paper, by measuring size distributions at high size resolution down to 1.3 nm, we extend the limit of the current technology. The current setup is limited to ion measurements. However, we envision that future research focused on the charging mechanisms could extend the technique to measure neutral aerosol particles as well, so that it will be possible to measure size distributions of ambient aerosols from 1 nm to 1 µm.oai:inspirehep.net:16638132016 |
spellingShingle | Nuclear Physics - Experiment Franchin, Alessandro Downard, Andy Kangasluoma, Juha Nieminen, Tuomo Lehtipalo, Katrianne Steiner, Gerhard Manninen, Hanna E Petäjä, Tuukka Flagan, Richard C Kulmala, Markku A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title | A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title_full | A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title_fullStr | A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title_full_unstemmed | A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title_short | A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations |
title_sort | new high-transmission inlet for the caltech nano-rdma for size distribution measurements of sub-3 nm ions at ambient concentrations |
topic | Nuclear Physics - Experiment |
url | https://dx.doi.org/10.5194/amt-9-2709-2016 http://cds.cern.ch/record/2310664 |
work_keys_str_mv | AT franchinalessandro anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT downardandy anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT kangasluomajuha anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT nieminentuomo anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT lehtipalokatrianne anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT steinergerhard anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT manninenhannae anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT petajatuukka anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT flaganrichardc anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT kulmalamarkku anewhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT franchinalessandro newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT downardandy newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT kangasluomajuha newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT nieminentuomo newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT lehtipalokatrianne newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT steinergerhard newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT manninenhannae newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT petajatuukka newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT flaganrichardc newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations AT kulmalamarkku newhightransmissioninletforthecaltechnanordmaforsizedistributionmeasurementsofsub3nmionsatambientconcentrations |