Cargando…
Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid
The accurate measurement of the gaseous sulfuric acid concentration is crucial within many fields of atmospheric science. Instruments utilizing chemical ionization mass spectrometry (CIMS) measuring H2SO4, therefore, require a careful calibration. We have set up a calibration source that can provide...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2012
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1021/jp212123n http://cds.cern.ch/record/2310666 |
_version_ | 1780957862844956672 |
---|---|
author | Kürten, Andreas Rondo, Linda Ehrhart, Sebastian Curtius, Joachim |
author_facet | Kürten, Andreas Rondo, Linda Ehrhart, Sebastian Curtius, Joachim |
author_sort | Kürten, Andreas |
collection | CERN |
description | The accurate measurement of the gaseous sulfuric acid concentration is crucial within many fields of atmospheric science. Instruments utilizing chemical ionization mass spectrometry (CIMS) measuring H2SO4, therefore, require a careful calibration. We have set up a calibration source that can provide a stable and adjustable concentration of H2SO4. The calibration system initiates the production of sulfuric acid through the oxidation of SO2 by OH. The hydroxyl radical is produced by UV photolysis of water vapor. A numerical model calculates the H2SO4 concentration provided at the outlet of the calibration source. From comparison of this concentration and the signals measured by CIMS, a calibration factor is derived. This factor is evaluated to be 1.1 × 1010 cm–3, which is in good agreement with values found in the literature for other CIMS instruments measuring H2SO4. The calibration system is described in detail and the results are discussed. Because the setup is external to the CIMS instrument, it offers the possibility for future CIMS intercomparison measurements by providing defined and stable concentrations of sulfuric acid. |
id | oai-inspirehep.net-1663822 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2012 |
record_format | invenio |
spelling | oai-inspirehep.net-16638222019-09-30T06:29:59Zdoi:10.1021/jp212123nhttp://cds.cern.ch/record/2310666engKürten, AndreasRondo, LindaEhrhart, SebastianCurtius, JoachimCalibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric AcidNuclear Physics - ExperimentThe accurate measurement of the gaseous sulfuric acid concentration is crucial within many fields of atmospheric science. Instruments utilizing chemical ionization mass spectrometry (CIMS) measuring H2SO4, therefore, require a careful calibration. We have set up a calibration source that can provide a stable and adjustable concentration of H2SO4. The calibration system initiates the production of sulfuric acid through the oxidation of SO2 by OH. The hydroxyl radical is produced by UV photolysis of water vapor. A numerical model calculates the H2SO4 concentration provided at the outlet of the calibration source. From comparison of this concentration and the signals measured by CIMS, a calibration factor is derived. This factor is evaluated to be 1.1 × 1010 cm–3, which is in good agreement with values found in the literature for other CIMS instruments measuring H2SO4. The calibration system is described in detail and the results are discussed. Because the setup is external to the CIMS instrument, it offers the possibility for future CIMS intercomparison measurements by providing defined and stable concentrations of sulfuric acid.oai:inspirehep.net:16638222012 |
spellingShingle | Nuclear Physics - Experiment Kürten, Andreas Rondo, Linda Ehrhart, Sebastian Curtius, Joachim Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title | Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title_full | Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title_fullStr | Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title_full_unstemmed | Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title_short | Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid |
title_sort | calibration of a chemical ionization mass spectrometer for the measurement of gaseous sulfuric acid |
topic | Nuclear Physics - Experiment |
url | https://dx.doi.org/10.1021/jp212123n http://cds.cern.ch/record/2310666 |
work_keys_str_mv | AT kurtenandreas calibrationofachemicalionizationmassspectrometerforthemeasurementofgaseoussulfuricacid AT rondolinda calibrationofachemicalionizationmassspectrometerforthemeasurementofgaseoussulfuricacid AT ehrhartsebastian calibrationofachemicalionizationmassspectrometerforthemeasurementofgaseoussulfuricacid AT curtiusjoachim calibrationofachemicalionizationmassspectrometerforthemeasurementofgaseoussulfuricacid |