Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry
The performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS) through the reaction of NO3– ions with H2SO4. The ion source is operated under atmospheric pressure and its desi...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5194/amt-4-437-2011 http://cds.cern.ch/record/2310668 |
_version_ | 1780957863271727104 |
---|---|
author | Kürten, A Rondo, L Ehrhart, S Curtius, J |
author_facet | Kürten, A Rondo, L Ehrhart, S Curtius, J |
author_sort | Kürten, A |
collection | CERN |
description | The performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS) through the reaction of NO3– ions with H2SO4. The ion source is operated under atmospheric pressure and its design is similar to the one of a radioactive (americium-241) ion source which has been used previously. The results show that the detection limit for the corona ion source is sufficiently good for most applications. For an integration time of 1 min it is ~6 × 104 molecule cm−3 of H2SO4. In addition, only a small cross-sensitivity to SO2 has been observed for concentrations as high as 1 ppmv in the sample gas. This low sensitivity to SO2 is achieved even without the addition of an OH scavenger. When comparing the new corona ion source with the americium ion source for the same provided H2SO4 concentration, both ion sources yield almost identical values. These features make the corona ion source investigated here favorable over the more commonly used radioactive ion sources for most applications where H2SO4 is measured by CIMS. |
id | oai-inspirehep.net-1663824 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | oai-inspirehep.net-16638242019-09-30T06:29:59Zdoi:10.5194/amt-4-437-2011http://cds.cern.ch/record/2310668engKürten, ARondo, LEhrhart, SCurtius, JPerformance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometryNuclear Physics - ExperimentThe performance of an ion source based on corona discharge has been studied. This source is used for the detection of gaseous sulfuric acid by chemical ionization mass spectrometry (CIMS) through the reaction of NO3– ions with H2SO4. The ion source is operated under atmospheric pressure and its design is similar to the one of a radioactive (americium-241) ion source which has been used previously. The results show that the detection limit for the corona ion source is sufficiently good for most applications. For an integration time of 1 min it is ~6 × 104 molecule cm−3 of H2SO4. In addition, only a small cross-sensitivity to SO2 has been observed for concentrations as high as 1 ppmv in the sample gas. This low sensitivity to SO2 is achieved even without the addition of an OH scavenger. When comparing the new corona ion source with the americium ion source for the same provided H2SO4 concentration, both ion sources yield almost identical values. These features make the corona ion source investigated here favorable over the more commonly used radioactive ion sources for most applications where H2SO4 is measured by CIMS.oai:inspirehep.net:16638242011 |
spellingShingle | Nuclear Physics - Experiment Kürten, A Rondo, L Ehrhart, S Curtius, J Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title | Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title_full | Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title_fullStr | Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title_full_unstemmed | Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title_short | Performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
title_sort | performance of a corona ion source for measurement of sulfuric acid by chemical ionization mass spectrometry |
topic | Nuclear Physics - Experiment |
url | https://dx.doi.org/10.5194/amt-4-437-2011 http://cds.cern.ch/record/2310668 |
work_keys_str_mv | AT kurtena performanceofacoronaionsourceformeasurementofsulfuricacidbychemicalionizationmassspectrometry AT rondol performanceofacoronaionsourceformeasurementofsulfuricacidbychemicalionizationmassspectrometry AT ehrharts performanceofacoronaionsourceformeasurementofsulfuricacidbychemicalionizationmassspectrometry AT curtiusj performanceofacoronaionsourceformeasurementofsulfuricacidbychemicalionizationmassspectrometry |