Cargando…
Small-pad Resistive Micromegas for Operation at Very High Rates
Resistive Micromegas detectors have proved to be suitable for precision tracking in dense particle rate environment up to few kHz/cm$^2$. Rate capability up to few MHz/cm$^2$ and low occupancy can be achieved by using few mm$^2$ readout pads. Such a rate capability will be required in upgrades of fo...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
SISSA
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.314.0793 http://cds.cern.ch/record/2314173 |
_version_ | 1780958098072010752 |
---|---|
author | Iengo, Paolo Alviggi, M G Camerlingo, M T Canale, V Della Pietra, M Di Donato, C Grieco, C Biglietti, M Iodice, M Petrucci, F Rossi, E Vecchio, V Farina, E Franchino, S Sekhniaidze, G Sidiropoulou, O |
author_facet | Iengo, Paolo Alviggi, M G Camerlingo, M T Canale, V Della Pietra, M Di Donato, C Grieco, C Biglietti, M Iodice, M Petrucci, F Rossi, E Vecchio, V Farina, E Franchino, S Sekhniaidze, G Sidiropoulou, O |
author_sort | Iengo, Paolo |
collection | CERN |
description | Resistive Micromegas detectors have proved to be suitable for precision tracking in dense particle rate environment up to few kHz/cm$^2$. Rate capability up to few MHz/cm$^2$ and low occupancy can be achieved by using few mm$^2$ readout pads. Such a rate capability will be required in upgrades of forward muon detectors of LHC experiments as well as in experiments at future colliders.We present the development of resistive micromegas with O(mm$^2$) pad readout aiming at precision tracking in high rate environment without efficiency loss up to several MHz/cm$^2$. A first small-pad prototype has been designed, constructed and tested. It consists of a matrix of 48x16 pads. Each pad has rectangular shape with a pitch of 1 and 3 mm in the two coordinates. The active surface is 4.8x4.8 cm$^2$ with a total number of 768 channels.Characterization and performance studies of the detector have been carried out by means of radioactive sources, high irradiation X-Rays and test beam. The results will be presented, along with recent developments aiming at the construction of fully scalable, thousands-channels small-pad detectors. |
id | oai-inspirehep.net-1664926 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
publisher | SISSA |
record_format | invenio |
spelling | oai-inspirehep.net-16649262019-10-15T15:28:40Zdoi:10.22323/1.314.0793http://cds.cern.ch/record/2314173engIengo, PaoloAlviggi, M GCamerlingo, M TCanale, VDella Pietra, MDi Donato, CGrieco, CBiglietti, MIodice, MPetrucci, FRossi, EVecchio, VFarina, EFranchino, SSekhniaidze, GSidiropoulou, OSmall-pad Resistive Micromegas for Operation at Very High RatesDetectors and Experimental TechniquesResistive Micromegas detectors have proved to be suitable for precision tracking in dense particle rate environment up to few kHz/cm$^2$. Rate capability up to few MHz/cm$^2$ and low occupancy can be achieved by using few mm$^2$ readout pads. Such a rate capability will be required in upgrades of forward muon detectors of LHC experiments as well as in experiments at future colliders.We present the development of resistive micromegas with O(mm$^2$) pad readout aiming at precision tracking in high rate environment without efficiency loss up to several MHz/cm$^2$. A first small-pad prototype has been designed, constructed and tested. It consists of a matrix of 48x16 pads. Each pad has rectangular shape with a pitch of 1 and 3 mm in the two coordinates. The active surface is 4.8x4.8 cm$^2$ with a total number of 768 channels.Characterization and performance studies of the detector have been carried out by means of radioactive sources, high irradiation X-Rays and test beam. The results will be presented, along with recent developments aiming at the construction of fully scalable, thousands-channels small-pad detectors.SISSAoai:inspirehep.net:16649262018 |
spellingShingle | Detectors and Experimental Techniques Iengo, Paolo Alviggi, M G Camerlingo, M T Canale, V Della Pietra, M Di Donato, C Grieco, C Biglietti, M Iodice, M Petrucci, F Rossi, E Vecchio, V Farina, E Franchino, S Sekhniaidze, G Sidiropoulou, O Small-pad Resistive Micromegas for Operation at Very High Rates |
title | Small-pad Resistive Micromegas for Operation at Very High Rates |
title_full | Small-pad Resistive Micromegas for Operation at Very High Rates |
title_fullStr | Small-pad Resistive Micromegas for Operation at Very High Rates |
title_full_unstemmed | Small-pad Resistive Micromegas for Operation at Very High Rates |
title_short | Small-pad Resistive Micromegas for Operation at Very High Rates |
title_sort | small-pad resistive micromegas for operation at very high rates |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.314.0793 http://cds.cern.ch/record/2314173 |
work_keys_str_mv | AT iengopaolo smallpadresistivemicromegasforoperationatveryhighrates AT alviggimg smallpadresistivemicromegasforoperationatveryhighrates AT camerlingomt smallpadresistivemicromegasforoperationatveryhighrates AT canalev smallpadresistivemicromegasforoperationatveryhighrates AT dellapietram smallpadresistivemicromegasforoperationatveryhighrates AT didonatoc smallpadresistivemicromegasforoperationatveryhighrates AT griecoc smallpadresistivemicromegasforoperationatveryhighrates AT bigliettim smallpadresistivemicromegasforoperationatveryhighrates AT iodicem smallpadresistivemicromegasforoperationatveryhighrates AT petruccif smallpadresistivemicromegasforoperationatveryhighrates AT rossie smallpadresistivemicromegasforoperationatveryhighrates AT vecchiov smallpadresistivemicromegasforoperationatveryhighrates AT farinae smallpadresistivemicromegasforoperationatveryhighrates AT franchinos smallpadresistivemicromegasforoperationatveryhighrates AT sekhniaidzeg smallpadresistivemicromegasforoperationatveryhighrates AT sidiropoulouo smallpadresistivemicromegasforoperationatveryhighrates |