Cargando…

DRM2: the readout board for the ALICE TOF upgrade

For the upgrade of the ALICE TOF electronics, we have designed a new version of the readout board, named DRM2, a card able to read the data coming from the TDC Readout Module boards via VME. A Microsemi Igloo2 FPGA acts as the VME master and interfaces the GBTx link for transmitting data and receivi...

Descripción completa

Detalles Bibliográficos
Autor principal: Falchieri, Davide
Lenguaje:eng
Publicado: SISSA 2018
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.313.0081
http://cds.cern.ch/record/2312286
_version_ 1780958016384794624
author Falchieri, Davide
author_facet Falchieri, Davide
author_sort Falchieri, Davide
collection CERN
description For the upgrade of the ALICE TOF electronics, we have designed a new version of the readout board, named DRM2, a card able to read the data coming from the TDC Readout Module boards via VME. A Microsemi Igloo2 FPGA acts as the VME master and interfaces the GBTx link for transmitting data and receiving triggers and a low-jitter clock. Compared to the old board, the DRM2 is able to cope with faster trigger rates and provides a larger data bandwidth towards the DAQ. The results of the measurements on the received clock jitter and data transmission performances in a full crate are given.
id oai-inspirehep.net-1665038
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
publisher SISSA
record_format invenio
spelling oai-inspirehep.net-16650382019-10-15T15:20:35Zdoi:10.22323/1.313.0081http://cds.cern.ch/record/2312286engFalchieri, DavideDRM2: the readout board for the ALICE TOF upgradeDetectors and Experimental TechniquesFor the upgrade of the ALICE TOF electronics, we have designed a new version of the readout board, named DRM2, a card able to read the data coming from the TDC Readout Module boards via VME. A Microsemi Igloo2 FPGA acts as the VME master and interfaces the GBTx link for transmitting data and receiving triggers and a low-jitter clock. Compared to the old board, the DRM2 is able to cope with faster trigger rates and provides a larger data bandwidth towards the DAQ. The results of the measurements on the received clock jitter and data transmission performances in a full crate are given.SISSAoai:inspirehep.net:16650382018
spellingShingle Detectors and Experimental Techniques
Falchieri, Davide
DRM2: the readout board for the ALICE TOF upgrade
title DRM2: the readout board for the ALICE TOF upgrade
title_full DRM2: the readout board for the ALICE TOF upgrade
title_fullStr DRM2: the readout board for the ALICE TOF upgrade
title_full_unstemmed DRM2: the readout board for the ALICE TOF upgrade
title_short DRM2: the readout board for the ALICE TOF upgrade
title_sort drm2: the readout board for the alice tof upgrade
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.313.0081
http://cds.cern.ch/record/2312286
work_keys_str_mv AT falchieridavide drm2thereadoutboardforthealicetofupgrade