Cargando…
HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
A modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used t...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/PPC.2017.8291257 https://dx.doi.org/10.1109/TPS.2018.2809446 http://cds.cern.ch/record/2315737 |
_version_ | 1780958198832824320 |
---|---|
author | Candolfi, S Viarouge, P Aguglia, D Cros, J |
author_facet | Candolfi, S Viarouge, P Aguglia, D Cros, J |
author_sort | Candolfi, S |
collection | CERN |
description | A modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used to investigate the influence of the detailed mechanical structure and the local winding configuration on pulse transformer operation performance. |
id | oai-inspirehep.net-1665660 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | oai-inspirehep.net-16656602019-09-30T06:29:59Zdoi:10.1109/PPC.2017.8291257doi:10.1109/TPS.2018.2809446http://cds.cern.ch/record/2315737engCandolfi, SViarouge, PAguglia, DCros, JHV pulse transformer generalized equivalent circuit identification based on detailed mechanical structureDetectors and Experimental TechniquesA modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used to investigate the influence of the detailed mechanical structure and the local winding configuration on pulse transformer operation performance.oai:inspirehep.net:16656602018 |
spellingShingle | Detectors and Experimental Techniques Candolfi, S Viarouge, P Aguglia, D Cros, J HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title | HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title_full | HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title_fullStr | HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title_full_unstemmed | HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title_short | HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
title_sort | hv pulse transformer generalized equivalent circuit identification based on detailed mechanical structure |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/PPC.2017.8291257 https://dx.doi.org/10.1109/TPS.2018.2809446 http://cds.cern.ch/record/2315737 |
work_keys_str_mv | AT candolfis hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure AT viarougep hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure AT agugliad hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure AT crosj hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure |