HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure

A modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used t...

Descripción completa

Detalles Bibliográficos
Autores principales: Candolfi, S, Viarouge, P, Aguglia, D, Cros, J
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/PPC.2017.8291257
https://dx.doi.org/10.1109/TPS.2018.2809446
http://cds.cern.ch/record/2315737
_version_ 1780958198832824320
author Candolfi, S
Viarouge, P
Aguglia, D
Cros, J
author_facet Candolfi, S
Viarouge, P
Aguglia, D
Cros, J
author_sort Candolfi, S
collection CERN
description A modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used to investigate the influence of the detailed mechanical structure and the local winding configuration on pulse transformer operation performance.
id oai-inspirehep.net-1665660
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16656602019-09-30T06:29:59Zdoi:10.1109/PPC.2017.8291257doi:10.1109/TPS.2018.2809446http://cds.cern.ch/record/2315737engCandolfi, SViarouge, PAguglia, DCros, JHV pulse transformer generalized equivalent circuit identification based on detailed mechanical structureDetectors and Experimental TechniquesA modelling methodology of High Voltage pulse transformers based on High Order Generalized Equivalent Circuits (HOGEC) identified from 3D FEA is applied to a prototype and experimental validation tests are performed. The identified High Order Generalized Equivalent Circuit of the prototype is used to investigate the influence of the detailed mechanical structure and the local winding configuration on pulse transformer operation performance.oai:inspirehep.net:16656602018
spellingShingle Detectors and Experimental Techniques
Candolfi, S
Viarouge, P
Aguglia, D
Cros, J
HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title_full HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title_fullStr HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title_full_unstemmed HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title_short HV pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
title_sort hv pulse transformer generalized equivalent circuit identification based on detailed mechanical structure
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/PPC.2017.8291257
https://dx.doi.org/10.1109/TPS.2018.2809446
http://cds.cern.ch/record/2315737
work_keys_str_mv AT candolfis hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure
AT viarougep hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure
AT agugliad hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure
AT crosj hvpulsetransformergeneralizedequivalentcircuitidentificationbasedondetailedmechanicalstructure