New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor

A new method of the quench detection systems (QDS) designed for the LHC 600 A corrector magnet circuits and 6 kA individual powered quadrupole (IPQ) magnet circuits is presented. In order to improve the dependability of QDS, a direct measurement of the current derivative is proposed. The quench dete...

Descripción completa

Detalles Bibliográficos
Autores principales: De Matteis, E, Calcoen, D, Denz, R, Siemko, A, Steckert, J, Storkensen, M B
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2018.2795553
http://cds.cern.ch/record/2315301
_version_ 1780958203180220416
author De Matteis, E
Calcoen, D
Denz, R
Siemko, A
Steckert, J
Storkensen, M B
author_facet De Matteis, E
Calcoen, D
Denz, R
Siemko, A
Steckert, J
Storkensen, M B
author_sort De Matteis, E
collection CERN
description A new method of the quench detection systems (QDS) designed for the LHC 600 A corrector magnet circuits and 6 kA individual powered quadrupole (IPQ) magnet circuits is presented. In order to improve the dependability of QDS, a direct measurement of the current derivative is proposed. The quench detection scheme for the 600 A corrector magnet circuits uses the current derivative numerically evaluated from a direct current measurement. In order to make the calculation stable, the current derivative is heavily filtered, thus introducing a significant phase shift, which restricts the operational range of circuit parameters such as the acceleration. For the 6-kA IPQ magnet circuits the main quench detection is based on a classical bridge configuration. The introduction of an additional detection channel for the direct measurement of the current derivative helps to overcome the lack of sensitivity to fully aperture symmetric quenches of the bridge configuration. Transformer-based current derivative sensors are currently under development, using cut cores for easy prototyping, performance control, and installation. Prototypes for the ±600 A current range and ramp rates between 0.1 and 5 A/s were built using different core materials (electrical steel and nanocrystalline cores) and pickup coils with 10 000 and 20 000 windings. In order to characterize the prototypes, the performance was defined in terms of mean sensitivity of the sensor response in [V/A/s] and the performance quality factor (PQF), defined as a percentage of nonlinearity of the response. An optimization procedure was implemented for finding the best configuration of the sensors, i.e., the air gap in the cut core in order to maximize the mean sensitivity and to minimize the PQF. The tests were carried out at different working points (current ranges and ramp rates) showing promising results (PQF <0.5% with a sensitivity of 5.5 mV/A/s).
id oai-inspirehep.net-1668900
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16689002019-09-30T06:29:59Zdoi:10.1109/TASC.2018.2795553http://cds.cern.ch/record/2315301engDe Matteis, ECalcoen, DDenz, RSiemko, ASteckert, JStorkensen, M BNew Method for Magnet Protection Systems Based on a Direct Current Derivative SensorAccelerators and Storage RingsA new method of the quench detection systems (QDS) designed for the LHC 600 A corrector magnet circuits and 6 kA individual powered quadrupole (IPQ) magnet circuits is presented. In order to improve the dependability of QDS, a direct measurement of the current derivative is proposed. The quench detection scheme for the 600 A corrector magnet circuits uses the current derivative numerically evaluated from a direct current measurement. In order to make the calculation stable, the current derivative is heavily filtered, thus introducing a significant phase shift, which restricts the operational range of circuit parameters such as the acceleration. For the 6-kA IPQ magnet circuits the main quench detection is based on a classical bridge configuration. The introduction of an additional detection channel for the direct measurement of the current derivative helps to overcome the lack of sensitivity to fully aperture symmetric quenches of the bridge configuration. Transformer-based current derivative sensors are currently under development, using cut cores for easy prototyping, performance control, and installation. Prototypes for the ±600 A current range and ramp rates between 0.1 and 5 A/s were built using different core materials (electrical steel and nanocrystalline cores) and pickup coils with 10 000 and 20 000 windings. In order to characterize the prototypes, the performance was defined in terms of mean sensitivity of the sensor response in [V/A/s] and the performance quality factor (PQF), defined as a percentage of nonlinearity of the response. An optimization procedure was implemented for finding the best configuration of the sensors, i.e., the air gap in the cut core in order to maximize the mean sensitivity and to minimize the PQF. The tests were carried out at different working points (current ranges and ramp rates) showing promising results (PQF <0.5% with a sensitivity of 5.5 mV/A/s).oai:inspirehep.net:16689002018
spellingShingle Accelerators and Storage Rings
De Matteis, E
Calcoen, D
Denz, R
Siemko, A
Steckert, J
Storkensen, M B
New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title_full New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title_fullStr New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title_full_unstemmed New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title_short New Method for Magnet Protection Systems Based on a Direct Current Derivative Sensor
title_sort new method for magnet protection systems based on a direct current derivative sensor
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1109/TASC.2018.2795553
http://cds.cern.ch/record/2315301
work_keys_str_mv AT dematteise newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor
AT calcoend newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor
AT denzr newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor
AT siemkoa newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor
AT steckertj newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor
AT storkensenmb newmethodformagnetprotectionsystemsbasedonadirectcurrentderivativesensor