Cargando…
In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities
A four wire measurement was used to measure the bulk RRR on two DQW Crab Cavities. The measurement procedure is explained and the values obtained for each cavity are compared together with the values obtained from Niobium samples of the same stock from which the cavities were manufactured. Measureme...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-SRF2017-TUPB014 http://cds.cern.ch/record/2673327 |
_version_ | 1780962521016958976 |
---|---|
author | Shipman, Nicholas Ben-Zvi, Ilan Burt, Graeme Castilla, Alejandro Hernández-Chahín, Karim Macpherson, Alick Mitchell, James |
author_facet | Shipman, Nicholas Ben-Zvi, Ilan Burt, Graeme Castilla, Alejandro Hernández-Chahín, Karim Macpherson, Alick Mitchell, James |
author_sort | Shipman, Nicholas |
collection | CERN |
description | A four wire measurement was used to measure the bulk RRR on two DQW Crab Cavities. The measurement procedure is explained and the values obtained for each cavity are compared together with the values obtained from Niobium samples of the same stock from which the cavities were manufactured. Measurement errors and carefully analysed and further improvements to the measurement procedure are suggested. |
id | oai-inspirehep.net-1669442 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | oai-inspirehep.net-16694422019-09-30T06:29:59Zdoi:10.18429/JACoW-SRF2017-TUPB014http://cds.cern.ch/record/2673327engShipman, NicholasBen-Zvi, IlanBurt, GraemeCastilla, AlejandroHernández-Chahín, KarimMacpherson, AlickMitchell, JamesIn-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab CavitiesAccelerators and Storage RingsA four wire measurement was used to measure the bulk RRR on two DQW Crab Cavities. The measurement procedure is explained and the values obtained for each cavity are compared together with the values obtained from Niobium samples of the same stock from which the cavities were manufactured. Measurement errors and carefully analysed and further improvements to the measurement procedure are suggested.oai:inspirehep.net:16694422018 |
spellingShingle | Accelerators and Storage Rings Shipman, Nicholas Ben-Zvi, Ilan Burt, Graeme Castilla, Alejandro Hernández-Chahín, Karim Macpherson, Alick Mitchell, James In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title | In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title_full | In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title_fullStr | In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title_full_unstemmed | In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title_short | In-situ Bulk Residual Resistivity Ratio Measurement on Double Quarter Wave Crab Cavities |
title_sort | in-situ bulk residual resistivity ratio measurement on double quarter wave crab cavities |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-SRF2017-TUPB014 http://cds.cern.ch/record/2673327 |
work_keys_str_mv | AT shipmannicholas insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT benzviilan insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT burtgraeme insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT castillaalejandro insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT hernandezchahinkarim insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT macphersonalick insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities AT mitchelljames insitubulkresidualresistivityratiomeasurementondoublequarterwavecrabcavities |