Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM

The radiation spectra in the CERN Large Hadron Collider (LHC) ranges from GeV down to thermal neutron levels. It is known that the thermal neutrons can significantly affect the electronic devices and systems exposed to the radiation environment of the tunnel and the shielded areas of the LHC. CERN’s...

Descripción completa

Detalles Bibliográficos
Autores principales: Cangialosi, C, Danzeca, S, Brucoli, M, Brugger, M, Masi, A
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2018.2829631
http://cds.cern.ch/record/2643841
_version_ 1780960360067497984
author Cangialosi, C
Danzeca, S
Brucoli, M
Brugger, M
Masi, A
author_facet Cangialosi, C
Danzeca, S
Brucoli, M
Brugger, M
Masi, A
author_sort Cangialosi, C
collection CERN
description The radiation spectra in the CERN Large Hadron Collider (LHC) ranges from GeV down to thermal neutron levels. It is known that the thermal neutrons can significantly affect the electronic devices and systems exposed to the radiation environment of the tunnel and the shielded areas of the LHC. CERN’s Radiation Monitoring system (RadMon) uses Static Random Access Memories (SRAM) to measure the contributions to the spectrum from both the High Energy Hadrons (>20MeV) and Thermal neutrons. A knowledge of the SRAM thermal neutron cross section is required for evaluating their contribution to the particle spectra and thus identifying the thermal neutron critical area. This paper describes a procedure to acquire, by means of RadMon system, the thermal neutron cross section of SRAM memories in a mixed field environment. The capabilities of the CERN High AcceleRator Mixed field facility (CHARM) to measure the thermal neutron sensitivity are then investigated. The procedure is evaluated by comparing the thermal neutron cross sections obtained at CHARM and the one measured using a pure thermal neutron beam. The same procedure could be applied to other devices to understand their susceptibility.
id oai-inspirehep.net-1670587
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16705872022-06-30T22:23:25Zdoi:10.1109/TNS.2018.2829631http://cds.cern.ch/record/2643841engCangialosi, CDanzeca, SBrucoli, MBrugger, MMasi, AThermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARMDetectors and Experimental TechniquesThe radiation spectra in the CERN Large Hadron Collider (LHC) ranges from GeV down to thermal neutron levels. It is known that the thermal neutrons can significantly affect the electronic devices and systems exposed to the radiation environment of the tunnel and the shielded areas of the LHC. CERN’s Radiation Monitoring system (RadMon) uses Static Random Access Memories (SRAM) to measure the contributions to the spectrum from both the High Energy Hadrons (>20MeV) and Thermal neutrons. A knowledge of the SRAM thermal neutron cross section is required for evaluating their contribution to the particle spectra and thus identifying the thermal neutron critical area. This paper describes a procedure to acquire, by means of RadMon system, the thermal neutron cross section of SRAM memories in a mixed field environment. The capabilities of the CERN High AcceleRator Mixed field facility (CHARM) to measure the thermal neutron sensitivity are then investigated. The procedure is evaluated by comparing the thermal neutron cross sections obtained at CHARM and the one measured using a pure thermal neutron beam. The same procedure could be applied to other devices to understand their susceptibility.oai:inspirehep.net:16705872018
spellingShingle Detectors and Experimental Techniques
Cangialosi, C
Danzeca, S
Brucoli, M
Brugger, M
Masi, A
Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title_full Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title_fullStr Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title_full_unstemmed Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title_short Thermal neutron SRAM detector characterization at the CERN Mixed Field Facility, CHARM
title_sort thermal neutron sram detector characterization at the cern mixed field facility, charm
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2018.2829631
http://cds.cern.ch/record/2643841
work_keys_str_mv AT cangialosic thermalneutronsramdetectorcharacterizationatthecernmixedfieldfacilitycharm
AT danzecas thermalneutronsramdetectorcharacterizationatthecernmixedfieldfacilitycharm
AT brucolim thermalneutronsramdetectorcharacterizationatthecernmixedfieldfacilitycharm
AT bruggerm thermalneutronsramdetectorcharacterizationatthecernmixedfieldfacilitycharm
AT masia thermalneutronsramdetectorcharacterizationatthecernmixedfieldfacilitycharm