Cargando…
Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters
The energy resolution of electromagnetic sampling calorimeters using silicon mosaics as active medium, has been measured for Pb and Fe absorbers at incoming electron energies E of 2, 4, and 6 GeV. The energy resolution, found for the Si/Pb sented by a(E)/E = pling frequency. The energy resolution ca...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
1993
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/NSSMIC.1993.701661 http://cds.cern.ch/record/2316796 |
_version_ | 1780958306335981568 |
---|---|
author | Bosetti, M Leroy, C. Pensotti, S. Penzo, A. Rancoita, P.G. Rattaggi, M. Redaelli, M. Salvato, G. Terzi, G. |
author_facet | Bosetti, M Leroy, C. Pensotti, S. Penzo, A. Rancoita, P.G. Rattaggi, M. Redaelli, M. Salvato, G. Terzi, G. |
author_sort | Bosetti, M |
collection | CERN |
description | The energy resolution of electromagnetic sampling calorimeters using silicon mosaics as active medium, has been measured for Pb and Fe absorbers at incoming electron energies E of 2, 4, and 6 GeV. The energy resolution, found for the Si/Pb sented by a(E)/E = pling frequency. The energy resolution can be rewritten as a function of the dead area energy losses (D): a(E)/E = (KO + all))% ,/- with KO = (17.6 f 0.3)%, (24.1&0.8)%, for Si/Pb, Si/Fe, respectively; a1 = 1.2f0.3 for both absorbers. |
id | oai-inspirehep.net-1671961 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1993 |
record_format | invenio |
spelling | oai-inspirehep.net-16719612019-09-30T06:29:59Zdoi:10.1109/NSSMIC.1993.701661http://cds.cern.ch/record/2316796engBosetti, MLeroy, C.Pensotti, S.Penzo, A.Rancoita, P.G.Rattaggi, M.Redaelli, M.Salvato, G.Terzi, G.Energy Resolution Of Si/Fe And Si/Pb Electromagnetic CalorimetersDetectors and Experimental TechniquesThe energy resolution of electromagnetic sampling calorimeters using silicon mosaics as active medium, has been measured for Pb and Fe absorbers at incoming electron energies E of 2, 4, and 6 GeV. The energy resolution, found for the Si/Pb sented by a(E)/E = pling frequency. The energy resolution can be rewritten as a function of the dead area energy losses (D): a(E)/E = (KO + all))% ,/- with KO = (17.6 f 0.3)%, (24.1&0.8)%, for Si/Pb, Si/Fe, respectively; a1 = 1.2f0.3 for both absorbers.oai:inspirehep.net:16719611993 |
spellingShingle | Detectors and Experimental Techniques Bosetti, M Leroy, C. Pensotti, S. Penzo, A. Rancoita, P.G. Rattaggi, M. Redaelli, M. Salvato, G. Terzi, G. Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title | Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title_full | Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title_fullStr | Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title_full_unstemmed | Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title_short | Energy Resolution Of Si/Fe And Si/Pb Electromagnetic Calorimeters |
title_sort | energy resolution of si/fe and si/pb electromagnetic calorimeters |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/NSSMIC.1993.701661 http://cds.cern.ch/record/2316796 |
work_keys_str_mv | AT bosettim energyresolutionofsifeandsipbelectromagneticcalorimeters AT leroyc energyresolutionofsifeandsipbelectromagneticcalorimeters AT pensottis energyresolutionofsifeandsipbelectromagneticcalorimeters AT penzoa energyresolutionofsifeandsipbelectromagneticcalorimeters AT rancoitapg energyresolutionofsifeandsipbelectromagneticcalorimeters AT rattaggim energyresolutionofsifeandsipbelectromagneticcalorimeters AT redaellim energyresolutionofsifeandsipbelectromagneticcalorimeters AT salvatog energyresolutionofsifeandsipbelectromagneticcalorimeters AT terzig energyresolutionofsifeandsipbelectromagneticcalorimeters |