Characterisation of the Medipix3 detector for 60 and 80 keV electrons

In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In sin...

Descripción completa

Detalles Bibliográficos
Autores principales: Mir, J A, Clough, R, MacInnes, R, Gough, C, Plackett, R, Shipsey, I, Sawada, H, MacLaren, I, Ballabriga, R, Maneuski, D, O'Shea, V, McGrouther, D, Kirkland, A I
Lenguaje:eng
Publicado: 2017
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.ultramic.2017.06.010
http://cds.cern.ch/record/2318933
_version_ 1780958456568610816
author Mir, J A
Clough, R
MacInnes, R
Gough, C
Plackett, R
Shipsey, I
Sawada, H
MacLaren, I
Ballabriga, R
Maneuski, D
O'Shea, V
McGrouther, D
Kirkland, A I
author_facet Mir, J A
Clough, R
MacInnes, R
Gough, C
Plackett, R
Shipsey, I
Sawada, H
MacLaren, I
Ballabriga, R
Maneuski, D
O'Shea, V
McGrouther, D
Kirkland, A I
author_sort Mir, J A
collection CERN
description In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging.
id oai-inspirehep.net-1673799
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2017
record_format invenio
spelling oai-inspirehep.net-16737992021-05-03T19:35:33Zdoi:10.1016/j.ultramic.2017.06.010http://cds.cern.ch/record/2318933engMir, J AClough, RMacInnes, RGough, CPlackett, RShipsey, ISawada, HMacLaren, IBallabriga, RManeuski, DO'Shea, VMcGrouther, DKirkland, A ICharacterisation of the Medipix3 detector for 60 and 80 keV electronsDetectors and Experimental TechniquesIn this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80 keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies <100 keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging.oai:inspirehep.net:16737992017
spellingShingle Detectors and Experimental Techniques
Mir, J A
Clough, R
MacInnes, R
Gough, C
Plackett, R
Shipsey, I
Sawada, H
MacLaren, I
Ballabriga, R
Maneuski, D
O'Shea, V
McGrouther, D
Kirkland, A I
Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title_full Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title_fullStr Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title_full_unstemmed Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title_short Characterisation of the Medipix3 detector for 60 and 80 keV electrons
title_sort characterisation of the medipix3 detector for 60 and 80 kev electrons
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.ultramic.2017.06.010
http://cds.cern.ch/record/2318933
work_keys_str_mv AT mirja characterisationofthemedipix3detectorfor60and80kevelectrons
AT cloughr characterisationofthemedipix3detectorfor60and80kevelectrons
AT macinnesr characterisationofthemedipix3detectorfor60and80kevelectrons
AT goughc characterisationofthemedipix3detectorfor60and80kevelectrons
AT plackettr characterisationofthemedipix3detectorfor60and80kevelectrons
AT shipseyi characterisationofthemedipix3detectorfor60and80kevelectrons
AT sawadah characterisationofthemedipix3detectorfor60and80kevelectrons
AT maclareni characterisationofthemedipix3detectorfor60and80kevelectrons
AT ballabrigar characterisationofthemedipix3detectorfor60and80kevelectrons
AT maneuskid characterisationofthemedipix3detectorfor60and80kevelectrons
AT osheav characterisationofthemedipix3detectorfor60and80kevelectrons
AT mcgroutherd characterisationofthemedipix3detectorfor60and80kevelectrons
AT kirklandai characterisationofthemedipix3detectorfor60and80kevelectrons