Cargando…

Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations

This paper discusses an instrument intercomparison performed in the high-energy field at the CERF facility at CERN between 2015 and 2017 (October 2015, May 2016, November 2016 and June 2017). Measurements were performed in several reference exposure locations with the CERN extended-range Bonner Sphe...

Descripción completa

Detalles Bibliográficos
Autores principales: Dinar, N, Pozzi, F, Silari, M, Puzo, P, Chiriotti, S, De Saint-Hubert, M, Vanhavere, F, Van Hoey, O, Orchard, G M, Waker, A J
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.radmeas.2018.05.008
http://cds.cern.ch/record/2640818
_version_ 1780960179739688960
author Dinar, N
Pozzi, F
Silari, M
Puzo, P
Chiriotti, S
De Saint-Hubert, M
Vanhavere, F
Van Hoey, O
Orchard, G M
Waker, A J
author_facet Dinar, N
Pozzi, F
Silari, M
Puzo, P
Chiriotti, S
De Saint-Hubert, M
Vanhavere, F
Van Hoey, O
Orchard, G M
Waker, A J
author_sort Dinar, N
collection CERN
description This paper discusses an instrument intercomparison performed in the high-energy field at the CERF facility at CERN between 2015 and 2017 (October 2015, May 2016, November 2016 and June 2017). Measurements were performed in several reference exposure locations with the CERN extended-range Bonner Sphere Spectrometer (BSS), a Berthold LB4611, the LINUS rem counter from CERN, the LUPIN rem counter from ELSE Nuclear, the FHT 762 Wide Energy Neutron Detection Instrument (WENDI-II) from Thermo Scientific, the LUDLUM MODEL 42–41 PRESCILA NEUTRON PROBE and two models of Tissue-equivalent proportional counters (TEPCs) from Far West Technologies. All results are compared with the latest FLUKA reference values from simulations performed in 2017.
id oai-inspirehep.net-1674846
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16748462019-09-30T06:29:59Zdoi:10.1016/j.radmeas.2018.05.008http://cds.cern.ch/record/2640818engDinar, NPozzi, FSilari, MPuzo, PChiriotti, SDe Saint-Hubert, MVanhavere, FVan Hoey, OOrchard, G MWaker, A JInstrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulationsDetectors and Experimental TechniquesDetectors and Experimental TechniquesThis paper discusses an instrument intercomparison performed in the high-energy field at the CERF facility at CERN between 2015 and 2017 (October 2015, May 2016, November 2016 and June 2017). Measurements were performed in several reference exposure locations with the CERN extended-range Bonner Sphere Spectrometer (BSS), a Berthold LB4611, the LINUS rem counter from CERN, the LUPIN rem counter from ELSE Nuclear, the FHT 762 Wide Energy Neutron Detection Instrument (WENDI-II) from Thermo Scientific, the LUDLUM MODEL 42–41 PRESCILA NEUTRON PROBE and two models of Tissue-equivalent proportional counters (TEPCs) from Far West Technologies. All results are compared with the latest FLUKA reference values from simulations performed in 2017.oai:inspirehep.net:16748462018
spellingShingle Detectors and Experimental Techniques
Detectors and Experimental Techniques
Dinar, N
Pozzi, F
Silari, M
Puzo, P
Chiriotti, S
De Saint-Hubert, M
Vanhavere, F
Van Hoey, O
Orchard, G M
Waker, A J
Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title_full Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title_fullStr Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title_full_unstemmed Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title_short Instrument intercomparison in the high-energy field at the CERN-EU reference field (CERF) facility and comparison with the 2017 FLUKA simulations
title_sort instrument intercomparison in the high-energy field at the cern-eu reference field (cerf) facility and comparison with the 2017 fluka simulations
topic Detectors and Experimental Techniques
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.radmeas.2018.05.008
http://cds.cern.ch/record/2640818
work_keys_str_mv AT dinarn instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT pozzif instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT silarim instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT puzop instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT chiriottis instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT desainthubertm instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT vanhaveref instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT vanhoeyo instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT orchardgm instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations
AT wakeraj instrumentintercomparisoninthehighenergyfieldatthecerneureferencefieldcerffacilityandcomparisonwiththe2017flukasimulations