A method for radiological characterization based on fluence conversion coefficients

Radiological characterization of components in accelerator environments is often required to ensure adequate radiation protection during maintenance, transport and handling as well as for the selection of the proper disposal pathway. The relevant quantities are typical the weighted sums of specific...

Descripción completa

Detalles Bibliográficos
Autor principal: Froeschl, Robert
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/1046/1/012006
http://cds.cern.ch/record/2636326
_version_ 1780959895449763840
author Froeschl, Robert
author_facet Froeschl, Robert
author_sort Froeschl, Robert
collection CERN
description Radiological characterization of components in accelerator environments is often required to ensure adequate radiation protection during maintenance, transport and handling as well as for the selection of the proper disposal pathway. The relevant quantities are typical the weighted sums of specific activities with radionuclide-specific weighting coefficients. Traditional methods based on Monte Carlo simulations are radionuclide creation-event based or the particle fluences in the regions of interest are scored and then off-line weighted with radionuclide production cross sections. The presented method bases the radiological characterization on a set of fluence conversion coefficients. For a given irradiation profile and cool-down time, radionuclide production cross-sections, material composition and radionuclide-specific weighting coefficients, a set of particle type and energy dependent fluence conversion coefficients is computed. These fluence conversion coefficients can then be used in a Monte Carlo transport code to perform on-line weighting to directly obtain the desired radiological characterization, either by using built-in multiplier features such as in the PHITS code or by writing a dedicated user routine such as for the FLUKA code. The presented method has been validated against the standard event-based methods directly available in Monte Carlo transport codes.
id oai-inspirehep.net-1678230
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16782302021-02-09T10:05:40Zdoi:10.1088/1742-6596/1046/1/012006http://cds.cern.ch/record/2636326engFroeschl, RobertA method for radiological characterization based on fluence conversion coefficientsAccelerators and Storage RingsRadiological characterization of components in accelerator environments is often required to ensure adequate radiation protection during maintenance, transport and handling as well as for the selection of the proper disposal pathway. The relevant quantities are typical the weighted sums of specific activities with radionuclide-specific weighting coefficients. Traditional methods based on Monte Carlo simulations are radionuclide creation-event based or the particle fluences in the regions of interest are scored and then off-line weighted with radionuclide production cross sections. The presented method bases the radiological characterization on a set of fluence conversion coefficients. For a given irradiation profile and cool-down time, radionuclide production cross-sections, material composition and radionuclide-specific weighting coefficients, a set of particle type and energy dependent fluence conversion coefficients is computed. These fluence conversion coefficients can then be used in a Monte Carlo transport code to perform on-line weighting to directly obtain the desired radiological characterization, either by using built-in multiplier features such as in the PHITS code or by writing a dedicated user routine such as for the FLUKA code. The presented method has been validated against the standard event-based methods directly available in Monte Carlo transport codes.oai:inspirehep.net:16782302018
spellingShingle Accelerators and Storage Rings
Froeschl, Robert
A method for radiological characterization based on fluence conversion coefficients
title A method for radiological characterization based on fluence conversion coefficients
title_full A method for radiological characterization based on fluence conversion coefficients
title_fullStr A method for radiological characterization based on fluence conversion coefficients
title_full_unstemmed A method for radiological characterization based on fluence conversion coefficients
title_short A method for radiological characterization based on fluence conversion coefficients
title_sort method for radiological characterization based on fluence conversion coefficients
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1088/1742-6596/1046/1/012006
http://cds.cern.ch/record/2636326
work_keys_str_mv AT froeschlrobert amethodforradiologicalcharacterizationbasedonfluenceconversioncoefficients
AT froeschlrobert methodforradiologicalcharacterizationbasedonfluenceconversioncoefficients