Cargando…
Fabrication and Cold Test of the Correction Cavity Chain for Klystron-Based CLIC
A proposed RF scheme based on correction cavity chain and storage cavity (CC-SC scheme) for klystron-based CLIC has the ability to generate flat output pulses. In the scheme, the correction cavity chain modulates the amplitude of the input pulse, while the storage cavity compresses the amplitude-mod...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2018-THPAL155 http://cds.cern.ch/record/2672611 |
Sumario: | A proposed RF scheme based on correction cavity chain and storage cavity (CC-SC scheme) for klystron-based CLIC has the ability to generate flat output pulses. In the scheme, the correction cavity chain modulates the amplitude of the input pulse, while the storage cavity compresses the amplitude-modulated pulse. Resonant cavities of the correction cavity chain are of a relatively low unloaded quality factor and of small size, which results in the compactness of the RF scheme. The first prototype of a correction cavity chain was fabricated and cold tested at Tsinghua University and then delivered to CERN for high power test. Both the results of the cold and high power tests show that the correction cavity chain is of good performance. Feasibility and stability of the pulse compression system based on CC-SC scheme were demonstrated. |
---|