Cargando…
Improvement of the Longitudinal Beam Transfer from PS to SPS at CERN
The beam transfer from the Proton Synchrotron (PS) to the Super Proton Synchrotron (SPS) at CERN is a critical process for the production of beams for the Large Hadron Collider (LHC). A bunch-to-bucket transfer is performed with the main drawback that the rf frequency in the SPS (200 MHz) is five ti...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2018-THPAF042 http://cds.cern.ch/record/2646058 |
Sumario: | The beam transfer from the Proton Synchrotron (PS) to the Super Proton Synchrotron (SPS) at CERN is a critical process for the production of beams for the Large Hadron Collider (LHC). A bunch-to-bucket transfer is performed with the main drawback that the rf frequency in the SPS (200 MHz) is five times higher than the one in the PS (40 MHz). The PS bunches are therefore shortened non-adiabatically before extraction by applying a fast rf voltage increase (bunch rotation) to fit them into the short rf buckets in the SPS. However, particles with large amplitude of synchrotron oscillations in the PS longitudinal phase space are not properly captured in the SPS. They contribute to losses at the injection plateau and at the start of acceleration in the SPS. In this contribution, we present measurements and simulations performed to identify the source of the uncaptured particles. The tails of the particle distribution were characterized by applying longitudinal shaving during acceleration. Furthermore, the rotated bunch distribution was improved by linearizing the rf voltage using a higher-harmonic rf cavity. |
---|