Cargando…

Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster

The measurement of the transverse emittance in an accelerator is a crucial parameter to evaluate the performance of the machine and to understand beam dynamics processes. In recent years, controlling and understanding the emittance became particularly relevant in the Proton Synchrotron Booster (PSB)...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Giovanni, Gian Piero, Albright, Simon, Forte, Vincenzo, Fraser, Matthew, Guidoboni, Greta, Mikulec, Bettina, Roncarolo, Federico, Santamaría García, Andrea
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2018-MOPMF054
http://cds.cern.ch/record/2649810
_version_ 1780960771765698560
author Di Giovanni, Gian Piero
Albright, Simon
Forte, Vincenzo
Fraser, Matthew
Guidoboni, Greta
Mikulec, Bettina
Roncarolo, Federico
Santamaría García, Andrea
author_facet Di Giovanni, Gian Piero
Albright, Simon
Forte, Vincenzo
Fraser, Matthew
Guidoboni, Greta
Mikulec, Bettina
Roncarolo, Federico
Santamaría García, Andrea
author_sort Di Giovanni, Gian Piero
collection CERN
description The measurement of the transverse emittance in an accelerator is a crucial parameter to evaluate the performance of the machine and to understand beam dynamics processes. In recent years, controlling and understanding the emittance became particularly relevant in the Proton Synchrotron Booster (PSB) at CERN as part of the LHC Injectors Upgrade (LIU). The LIU project is a necessary step to achieve the goals of the High-Luminosity LHC project. In this framework, an accurate and reliable emittance measurement of high brightness beams is mandatory to study the brightness reach of the LHC injectors. In the PSB there are two main instruments available for emittance measurements: wire scanners and secondary-emission (SEM) grids. In this paper emittance measurements performed during the 2017 physics run with these two systems are compared, taking into account various systematic error sources.
id oai-inspirehep.net-1691343
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16913432019-09-30T06:29:59Zdoi:10.18429/JACoW-IPAC2018-MOPMF054http://cds.cern.ch/record/2649810engDi Giovanni, Gian PieroAlbright, SimonForte, VincenzoFraser, MatthewGuidoboni, GretaMikulec, BettinaRoncarolo, FedericoSantamaría García, AndreaComparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron BoosterAccelerators and Storage RingsThe measurement of the transverse emittance in an accelerator is a crucial parameter to evaluate the performance of the machine and to understand beam dynamics processes. In recent years, controlling and understanding the emittance became particularly relevant in the Proton Synchrotron Booster (PSB) at CERN as part of the LHC Injectors Upgrade (LIU). The LIU project is a necessary step to achieve the goals of the High-Luminosity LHC project. In this framework, an accurate and reliable emittance measurement of high brightness beams is mandatory to study the brightness reach of the LHC injectors. In the PSB there are two main instruments available for emittance measurements: wire scanners and secondary-emission (SEM) grids. In this paper emittance measurements performed during the 2017 physics run with these two systems are compared, taking into account various systematic error sources.CERN-ACC-2018-115oai:inspirehep.net:16913432018
spellingShingle Accelerators and Storage Rings
Di Giovanni, Gian Piero
Albright, Simon
Forte, Vincenzo
Fraser, Matthew
Guidoboni, Greta
Mikulec, Bettina
Roncarolo, Federico
Santamaría García, Andrea
Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title_full Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title_fullStr Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title_full_unstemmed Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title_short Comparison of Different Transverse Emittance Measurement Techniques in the Proton Synchrotron Booster
title_sort comparison of different transverse emittance measurement techniques in the proton synchrotron booster
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2018-MOPMF054
http://cds.cern.ch/record/2649810
work_keys_str_mv AT digiovannigianpiero comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT albrightsimon comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT fortevincenzo comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT frasermatthew comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT guidobonigreta comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT mikulecbettina comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT roncarolofederico comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster
AT santamariagarciaandrea comparisonofdifferenttransverseemittancemeasurementtechniquesintheprotonsynchrotronbooster