Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility

Here we investigate how inserts of various densities (0.001-2.2 g/cm³) affect the dose distribution properties of VHEE beams at ~150 MeV. A range variation comparison was also made with clinical proton beams using TOPAS/GEANT4 Monte Carlo simulations. In addition, we assess the viability of scatteri...

Descripción completa

Detalles Bibliográficos
Autores principales: Lagzda, Agnese, Aitkenhead, Adam, Corsini, Roberto, Farabolini, Wilfrid, Jones, Roger, Kirkby, Karen, MacKay, Ranald, Van Herk, Marcel
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2018-MOPML023
http://cds.cern.ch/record/2664975
_version_ 1780961946874413056
author Lagzda, Agnese
Aitkenhead, Adam
Corsini, Roberto
Farabolini, Wilfrid
Jones, Roger
Kirkby, Karen
MacKay, Ranald
Van Herk, Marcel
author_facet Lagzda, Agnese
Aitkenhead, Adam
Corsini, Roberto
Farabolini, Wilfrid
Jones, Roger
Kirkby, Karen
MacKay, Ranald
Van Herk, Marcel
author_sort Lagzda, Agnese
collection CERN
description Here we investigate how inserts of various densities (0.001-2.2 g/cm³) affect the dose distribution properties of VHEE beams at ~150 MeV. A range variation comparison was also made with clinical proton beams using TOPAS/GEANT4 Monte Carlo simulations. In addition, we assess the viability of scattering foils for optimizing the size of VHEE beams for radiotherapy purposes. The experiments were conducted at CERN's CLEAR user facility.
id oai-inspirehep.net-1691453
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-16914532019-09-30T06:29:59Zdoi:10.18429/JACoW-IPAC2018-MOPML023http://cds.cern.ch/record/2664975engLagzda, AgneseAitkenhead, AdamCorsini, RobertoFarabolini, WilfridJones, RogerKirkby, KarenMacKay, RanaldVan Herk, MarcelVery-High Energy Electron (VHEE) Studies at CERN's CLEAR User FacilityAccelerators and Storage RingsHere we investigate how inserts of various densities (0.001-2.2 g/cm³) affect the dose distribution properties of VHEE beams at ~150 MeV. A range variation comparison was also made with clinical proton beams using TOPAS/GEANT4 Monte Carlo simulations. In addition, we assess the viability of scattering foils for optimizing the size of VHEE beams for radiotherapy purposes. The experiments were conducted at CERN's CLEAR user facility.oai:inspirehep.net:16914532018
spellingShingle Accelerators and Storage Rings
Lagzda, Agnese
Aitkenhead, Adam
Corsini, Roberto
Farabolini, Wilfrid
Jones, Roger
Kirkby, Karen
MacKay, Ranald
Van Herk, Marcel
Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title_full Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title_fullStr Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title_full_unstemmed Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title_short Very-High Energy Electron (VHEE) Studies at CERN's CLEAR User Facility
title_sort very-high energy electron (vhee) studies at cern's clear user facility
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2018-MOPML023
http://cds.cern.ch/record/2664975
work_keys_str_mv AT lagzdaagnese veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT aitkenheadadam veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT corsiniroberto veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT faraboliniwilfrid veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT jonesroger veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT kirkbykaren veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT mackayranald veryhighenergyelectronvheestudiesatcernsclearuserfacility
AT vanherkmarcel veryhighenergyelectronvheestudiesatcernsclearuserfacility