Cargando…

Sensor array calibration by a single reference in presence of measurand non-linear gradient

A calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctu...

Descripción completa

Detalles Bibliográficos
Autores principales: Arpaia, P, Baccigalupi, C, Cesaro, U, Chadli, M, Coppier, H, Pezzetti, M, Severino, G
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.1109/I2MTC.2018.8409713
http://cds.cern.ch/record/2682987
_version_ 1780963225178734592
author Arpaia, P
Baccigalupi, C
Cesaro, U
Chadli, M
Coppier, H
Pezzetti, M
Severino, G
author_facet Arpaia, P
Baccigalupi, C
Cesaro, U
Chadli, M
Coppier, H
Pezzetti, M
Severino, G
author_sort Arpaia, P
collection CERN
description A calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctual reference sensor, are avoided. A proof-of-principle demonstration is carried out within the case study of a thermistors array obtaining compatible result with respect to a standard method which requires a reference sensor for each element of the sensor array. Thus, the complexity (and cost) of standard calbration setups is reduced by using a single reference sensor without sacrifying significantly the calibration accuracy.
id oai-inspirehep.net-1702504
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
record_format invenio
spelling oai-inspirehep.net-17025042019-09-30T06:29:59Zdoi:10.1109/I2MTC.2018.8409713http://cds.cern.ch/record/2682987engArpaia, PBaccigalupi, CCesaro, UChadli, MCoppier, HPezzetti, MSeverino, GSensor array calibration by a single reference in presence of measurand non-linear gradientDetectors and Experimental TechniquesA calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctual reference sensor, are avoided. A proof-of-principle demonstration is carried out within the case study of a thermistors array obtaining compatible result with respect to a standard method which requires a reference sensor for each element of the sensor array. Thus, the complexity (and cost) of standard calbration setups is reduced by using a single reference sensor without sacrifying significantly the calibration accuracy.oai:inspirehep.net:17025042018
spellingShingle Detectors and Experimental Techniques
Arpaia, P
Baccigalupi, C
Cesaro, U
Chadli, M
Coppier, H
Pezzetti, M
Severino, G
Sensor array calibration by a single reference in presence of measurand non-linear gradient
title Sensor array calibration by a single reference in presence of measurand non-linear gradient
title_full Sensor array calibration by a single reference in presence of measurand non-linear gradient
title_fullStr Sensor array calibration by a single reference in presence of measurand non-linear gradient
title_full_unstemmed Sensor array calibration by a single reference in presence of measurand non-linear gradient
title_short Sensor array calibration by a single reference in presence of measurand non-linear gradient
title_sort sensor array calibration by a single reference in presence of measurand non-linear gradient
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/I2MTC.2018.8409713
http://cds.cern.ch/record/2682987
work_keys_str_mv AT arpaiap sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT baccigalupic sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT cesarou sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT chadlim sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT coppierh sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT pezzettim sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient
AT severinog sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient