Cargando…
Sensor array calibration by a single reference in presence of measurand non-linear gradient
A calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctu...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/I2MTC.2018.8409713 http://cds.cern.ch/record/2682987 |
_version_ | 1780963225178734592 |
---|---|
author | Arpaia, P Baccigalupi, C Cesaro, U Chadli, M Coppier, H Pezzetti, M Severino, G |
author_facet | Arpaia, P Baccigalupi, C Cesaro, U Chadli, M Coppier, H Pezzetti, M Severino, G |
author_sort | Arpaia, P |
collection | CERN |
description | A calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctual reference sensor, are avoided. A proof-of-principle demonstration is carried out within the case study of a thermistors array obtaining compatible result with respect to a standard method which requires a reference sensor for each element of the sensor array. Thus, the complexity (and cost) of standard calbration setups is reduced by using a single reference sensor without sacrifying significantly the calibration accuracy. |
id | oai-inspirehep.net-1702504 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | oai-inspirehep.net-17025042019-09-30T06:29:59Zdoi:10.1109/I2MTC.2018.8409713http://cds.cern.ch/record/2682987engArpaia, PBaccigalupi, CCesaro, UChadli, MCoppier, HPezzetti, MSeverino, GSensor array calibration by a single reference in presence of measurand non-linear gradientDetectors and Experimental TechniquesA calibration method exploiting a single external reference is proposed for sensors arrays in presence of a measurand non-linear gradient in the system under test. The calibration artifacts due to a non-uniform distribution of the measurand in the system under test, not detected by the single punctual reference sensor, are avoided. A proof-of-principle demonstration is carried out within the case study of a thermistors array obtaining compatible result with respect to a standard method which requires a reference sensor for each element of the sensor array. Thus, the complexity (and cost) of standard calbration setups is reduced by using a single reference sensor without sacrifying significantly the calibration accuracy.oai:inspirehep.net:17025042018 |
spellingShingle | Detectors and Experimental Techniques Arpaia, P Baccigalupi, C Cesaro, U Chadli, M Coppier, H Pezzetti, M Severino, G Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title | Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title_full | Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title_fullStr | Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title_full_unstemmed | Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title_short | Sensor array calibration by a single reference in presence of measurand non-linear gradient |
title_sort | sensor array calibration by a single reference in presence of measurand non-linear gradient |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/I2MTC.2018.8409713 http://cds.cern.ch/record/2682987 |
work_keys_str_mv | AT arpaiap sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT baccigalupic sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT cesarou sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT chadlim sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT coppierh sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT pezzettim sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient AT severinog sensorarraycalibrationbyasinglereferenceinpresenceofmeasurandnonlineargradient |