Cargando…

Dose gradient assessment at the new CERN CHARM irradiation facility

CERN CHARM facility provides a unique complex radiation environment characterized by particle energy spectra representative of high-energy accelerators, ground and atmospheric conditions and space applications. CHARM is conceived to be an irradiation facility for the qualification of large electroni...

Descripción completa

Detalles Bibliográficos
Autores principales: Infantino, A, Cangialosi, C, Krawina, M, Brucoli, M, Brugger, M, De Carvalho Saraiva, J P, Danzeca, S
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.radphyschem.2018.09.001
http://cds.cern.ch/record/2646876
_version_ 1780960583924842496
author Infantino, A
Cangialosi, C
Krawina, M
Brucoli, M
Brugger, M
De Carvalho Saraiva, J P
Danzeca, S
author_facet Infantino, A
Cangialosi, C
Krawina, M
Brucoli, M
Brugger, M
De Carvalho Saraiva, J P
Danzeca, S
author_sort Infantino, A
collection CERN
description CERN CHARM facility provides a unique complex radiation environment characterized by particle energy spectra representative of high-energy accelerators, ground and atmospheric conditions and space applications. CHARM is conceived to be an irradiation facility for the qualification of large electronic systems and components in a mixed field radiation environment generated from the interaction of a 24 GeV/c proton beam with a copper or aluminium target. A movable shielding made of layers of concrete and iron allows changing the hardness and the particle population (neutron, proton, kaon, pion, muon, electron, positron, and photon) in predefined test locations. To ensure a full representativeness and reproducibility of the tests, an accurate dosimetry of the complex mixed irradiation field is mandatory. The significant size of the available test area, the multiple facility configurations as well as the strong radiation gradient present in some of the test locations make the radiation monitoring a challenge. This work provides a first characterization of the absorbed dose gradient in two specific test locations: T0, a high dose rate test location close the target revolver; R11, a standard test location for irradiation tests on electronics equipment and devices. Experimental measurements conducted with RPL dosimeters and pMOS RadFET sensors were coupled with FLUKA Monte Carlo simulation. The concluding comparison shows an overall good agreement, considering the strong dose gradient and the limitation of the dosimeters in the mixed field environment.
id oai-inspirehep.net-1703317
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17033172022-08-10T12:23:42Zdoi:10.1016/j.radphyschem.2018.09.001http://cds.cern.ch/record/2646876engInfantino, ACangialosi, CKrawina, MBrucoli, MBrugger, MDe Carvalho Saraiva, J PDanzeca, SDose gradient assessment at the new CERN CHARM irradiation facilityAccelerators and Storage RingsCERN CHARM facility provides a unique complex radiation environment characterized by particle energy spectra representative of high-energy accelerators, ground and atmospheric conditions and space applications. CHARM is conceived to be an irradiation facility for the qualification of large electronic systems and components in a mixed field radiation environment generated from the interaction of a 24 GeV/c proton beam with a copper or aluminium target. A movable shielding made of layers of concrete and iron allows changing the hardness and the particle population (neutron, proton, kaon, pion, muon, electron, positron, and photon) in predefined test locations. To ensure a full representativeness and reproducibility of the tests, an accurate dosimetry of the complex mixed irradiation field is mandatory. The significant size of the available test area, the multiple facility configurations as well as the strong radiation gradient present in some of the test locations make the radiation monitoring a challenge. This work provides a first characterization of the absorbed dose gradient in two specific test locations: T0, a high dose rate test location close the target revolver; R11, a standard test location for irradiation tests on electronics equipment and devices. Experimental measurements conducted with RPL dosimeters and pMOS RadFET sensors were coupled with FLUKA Monte Carlo simulation. The concluding comparison shows an overall good agreement, considering the strong dose gradient and the limitation of the dosimeters in the mixed field environment.oai:inspirehep.net:17033172019
spellingShingle Accelerators and Storage Rings
Infantino, A
Cangialosi, C
Krawina, M
Brucoli, M
Brugger, M
De Carvalho Saraiva, J P
Danzeca, S
Dose gradient assessment at the new CERN CHARM irradiation facility
title Dose gradient assessment at the new CERN CHARM irradiation facility
title_full Dose gradient assessment at the new CERN CHARM irradiation facility
title_fullStr Dose gradient assessment at the new CERN CHARM irradiation facility
title_full_unstemmed Dose gradient assessment at the new CERN CHARM irradiation facility
title_short Dose gradient assessment at the new CERN CHARM irradiation facility
title_sort dose gradient assessment at the new cern charm irradiation facility
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1016/j.radphyschem.2018.09.001
http://cds.cern.ch/record/2646876
work_keys_str_mv AT infantinoa dosegradientassessmentatthenewcerncharmirradiationfacility
AT cangialosic dosegradientassessmentatthenewcerncharmirradiationfacility
AT krawinam dosegradientassessmentatthenewcerncharmirradiationfacility
AT brucolim dosegradientassessmentatthenewcerncharmirradiationfacility
AT bruggerm dosegradientassessmentatthenewcerncharmirradiationfacility
AT decarvalhosaraivajp dosegradientassessmentatthenewcerncharmirradiationfacility
AT danzecas dosegradientassessmentatthenewcerncharmirradiationfacility