Cargando…

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

A beam test of the ScECAL prototype module has been performed in the period Aug 19 - Oct 04 2008 at FNAL meson beam test facility. This beam test is the first comprehensive beam test for the ScECAL combined with Analog ScHCAL using 1 - 32 GeV electron, pion and muon beams. As a preliminary result of...

Descripción completa

Detalles Bibliográficos
Autor principal: CALICE Collaboration
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/2669459
_version_ 1780962215174602752
author CALICE Collaboration
author_facet CALICE Collaboration
author_sort CALICE Collaboration
collection CERN
description A beam test of the ScECAL prototype module has been performed in the period Aug 19 - Oct 04 2008 at FNAL meson beam test facility. This beam test is the first comprehensive beam test for the ScECAL combined with Analog ScHCAL using 1 - 32 GeV electron, pion and muon beams. As a preliminary result of the first stage analysis, we obtain for the ScECAL a relative energy resolution for single electrons of σE/E = (1.44±0.02)%⊕(15.15±0.03)/$/ \sqrt{E_{beam} GeV)} \%$, with the quoted uncertainty purely statistical. The deviation from the perfect linear response is found to be less than 6%.
id oai-inspirehep.net-1712598
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling oai-inspirehep.net-17125982019-09-30T06:29:59Zhttp://cds.cern.ch/record/2669459engCALICE CollaborationFirst Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008Detectors and Experimental TechniquesDetectors and Experimental TechniquesA beam test of the ScECAL prototype module has been performed in the period Aug 19 - Oct 04 2008 at FNAL meson beam test facility. This beam test is the first comprehensive beam test for the ScECAL combined with Analog ScHCAL using 1 - 32 GeV electron, pion and muon beams. As a preliminary result of the first stage analysis, we obtain for the ScECAL a relative energy resolution for single electrons of σE/E = (1.44±0.02)%⊕(15.15±0.03)/$/ \sqrt{E_{beam} GeV)} \%$, with the quoted uncertainty purely statistical. The deviation from the perfect linear response is found to be less than 6%.CALICE Analysis Note CAN-016CALICE-CAN-2010-005CALICE Analysis Note CAN-016aCALICE Analysis Note CAN-016bCALICE Analysis Note CAN-016coai:inspirehep.net:17125982010
spellingShingle Detectors and Experimental Techniques
Detectors and Experimental Techniques
CALICE Collaboration
First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title_full First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title_fullStr First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title_full_unstemmed First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title_short First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008
title_sort first stage analysis of the energy response and resolution of the scintillator ecal in the beam test at fnal, 2008
topic Detectors and Experimental Techniques
Detectors and Experimental Techniques
url http://cds.cern.ch/record/2669459
work_keys_str_mv AT calicecollaboration firststageanalysisoftheenergyresponseandresolutionofthescintillatorecalinthebeamtestatfnal2008