Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype

Electron data collected in the 2006 CERN beam test were used to evaluate the position and angular resolution of the SiW electromagnetic calorimeter. The angular resolution was evaluated to be (106±2/$\sqrt{E(GeV})⊕ 0.004±0.001) mrad along x and (100±2/$\sqrt{E(GeV})⊕0.014±0.001) mrad in the y direct...

Descripción completa

Detalles Bibliográficos
Autor principal: CALICE Collaboration
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/2669469
_version_ 1780962217328377856
author CALICE Collaboration
author_facet CALICE Collaboration
author_sort CALICE Collaboration
collection CERN
description Electron data collected in the 2006 CERN beam test were used to evaluate the position and angular resolution of the SiW electromagnetic calorimeter. The angular resolution was evaluated to be (106±2/$\sqrt{E(GeV})⊕ 0.004±0.001) mrad along x and (100±2/$\sqrt{E(GeV})⊕0.014±0.001) mrad in the y direction. The resolution along the x axis was better than along the y axis due to the staggering of layers in the x direction. The upper bound on the position resolution was evaluated after correcting for the calorimeter cell structure. This limit is due to the contribution of the tracking system to the position resolution. The results were (15.7 ± 0.2/E ⊕ 0 ± 0.4/E ⊕ 1.04 ± 0.01) mm and (15.3 ± 0.5/E ⊕ 1.4 ± 0.6/√E ⊕ 0.94 ± 0.02) mm for the x and y axis respectively.
id oai-inspirehep.net-1712608
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling oai-inspirehep.net-17126082019-09-30T06:29:59Zhttp://cds.cern.ch/record/2669469engCALICE CollaborationStudy of position and angular resolution for electron showers measured with the electromagnetic SiW prototypeDetectors and Experimental TechniquesDetectors and Experimental TechniquesElectron data collected in the 2006 CERN beam test were used to evaluate the position and angular resolution of the SiW electromagnetic calorimeter. The angular resolution was evaluated to be (106±2/$\sqrt{E(GeV})⊕ 0.004±0.001) mrad along x and (100±2/$\sqrt{E(GeV})⊕0.014±0.001) mrad in the y direction. The resolution along the x axis was better than along the y axis due to the staggering of layers in the x direction. The upper bound on the position resolution was evaluated after correcting for the calorimeter cell structure. This limit is due to the contribution of the tracking system to the position resolution. The results were (15.7 ± 0.2/E ⊕ 0 ± 0.4/E ⊕ 1.04 ± 0.01) mm and (15.3 ± 0.5/E ⊕ 1.4 ± 0.6/√E ⊕ 0.94 ± 0.02) mm for the x and y axis respectively.CALICE Analysis Note CAN-017CALICE-CAN-2010-004oai:inspirehep.net:17126082009
spellingShingle Detectors and Experimental Techniques
Detectors and Experimental Techniques
CALICE Collaboration
Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title_full Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title_fullStr Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title_full_unstemmed Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title_short Study of position and angular resolution for electron showers measured with the electromagnetic SiW prototype
title_sort study of position and angular resolution for electron showers measured with the electromagnetic siw prototype
topic Detectors and Experimental Techniques
Detectors and Experimental Techniques
url http://cds.cern.ch/record/2669469
work_keys_str_mv AT calicecollaboration studyofpositionandangularresolutionforelectronshowersmeasuredwiththeelectromagneticsiwprototype