Cargando…

Multigap Resistive Plate Chamber read out by 1×1cm2 pads with the NINO ASIC

The Multigap Resistive Plate Chamber (MRPC) is a possible candidate for the Semi-Digital Hadronic Calorimeter (SDHCAL). Two 4.5×20cm2 active area MRPCs have been built to study the time resolution using the NINO ASIC as front-end electronics. The granularity of the active area is provided by a 4 × 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Z, Kim, D W, Williams, M C S, Zichichi, A, Zuyeuski, R
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2018.12.043
http://cds.cern.ch/record/2665503
Descripción
Sumario:The Multigap Resistive Plate Chamber (MRPC) is a possible candidate for the Semi-Digital Hadronic Calorimeter (SDHCAL). Two 4.5×20cm2 active area MRPCs have been built to study the time resolution using the NINO ASIC as front-end electronics. The granularity of the active area is provided by a 4 × 16 array of 1×1cm2 pick-up pads. Two different designs have been used for the two chambers: a six gas gap MRPC (6-gap MRPC) with a 220μm gap size and a ten gas gap MRPC (10-gap MRPC) with a 160μm gap size. An efficiency of 95% and 97% has been reached respectively. A time resolution of 50 ps for the 6-gap MRPC and 30 ps for the 10-gap MRPC has been achieved. The multiplicity study of this two MRPCs shows that a large fraction of the single hit is recorded in the events (71% for 6-gap MRPC and 64% for 10-gap MRPC).