Cargando…

Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam

This note presents results obtained with the combined scintillator-SiPM calorimeter system consisting of the Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker in the energy range 4–32 GeV at the FNAL testbeam campaign in 2009. The analysis in...

Descripción completa

Detalles Bibliográficos
Autor principal: CALICE Collaboration
Lenguaje:eng
Publicado: 2016
Materias:
Acceso en línea:http://cds.cern.ch/record/2669485
_version_ 1780962220777144320
author CALICE Collaboration
author_facet CALICE Collaboration
author_sort CALICE Collaboration
collection CERN
description This note presents results obtained with the combined scintillator-SiPM calorimeter system consisting of the Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker in the energy range 4–32 GeV at the FNAL testbeam campaign in 2009. The analysis includes longitudinal profiles as well as response linearity and energy resolution of pions for standard and software compensation reconstruction. The results are compared to several Geant 4 physics lists in software versions 9.6 and 10.1.
id oai-inspirehep.net-1712882
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2016
record_format invenio
spelling oai-inspirehep.net-17128822019-09-30T06:29:59Zhttp://cds.cern.ch/record/2669485engCALICE CollaborationPion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL TestbeamDetectors and Experimental TechniquesDetectors and Experimental TechniquesThis note presents results obtained with the combined scintillator-SiPM calorimeter system consisting of the Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker in the energy range 4–32 GeV at the FNAL testbeam campaign in 2009. The analysis includes longitudinal profiles as well as response linearity and energy resolution of pions for standard and software compensation reconstruction. The results are compared to several Geant 4 physics lists in software versions 9.6 and 10.1.CALICE Analysis Note CAN-056CALICE-CAN-2016-003oai:inspirehep.net:17128822016
spellingShingle Detectors and Experimental Techniques
Detectors and Experimental Techniques
CALICE Collaboration
Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title_full Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title_fullStr Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title_full_unstemmed Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title_short Pion Response and Resolution in a Combined Scintillator Calorimeter System in the FNAL Testbeam
title_sort pion response and resolution in a combined scintillator calorimeter system in the fnal testbeam
topic Detectors and Experimental Techniques
Detectors and Experimental Techniques
url http://cds.cern.ch/record/2669485
work_keys_str_mv AT calicecollaboration pionresponseandresolutioninacombinedscintillatorcalorimetersysteminthefnaltestbeam