Cargando…

Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers

The ATLAS muon spectrometer comprises excellent muon trigger capabilities and high muon momentum resolution up to the TeV scale. Yet, in a small region between the barrel and end-cap parts of the muon spectrometer, a non-negligible muon trigger rate from charged particles not emerging from the pp in...

Descripción completa

Detalles Bibliográficos
Autor principal: Walbrecht, Verena Maria
Lenguaje:eng
Publicado: SISSA 2018
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.321.0083
http://cds.cern.ch/record/2668904
_version_ 1780962226134319104
author Walbrecht, Verena Maria
author_facet Walbrecht, Verena Maria
author_sort Walbrecht, Verena Maria
collection CERN
description The ATLAS muon spectrometer comprises excellent muon trigger capabilities and high muon momentum resolution up to the TeV scale. Yet, in a small region between the barrel and end-cap parts of the muon spectrometer, a non-negligible muon trigger rate from charged particles not emerging from the pp interaction point has been observed.To prevent such fake triggers, the end of the inner ring of the muon spectrometer barrel in the barrel end-cap transition region, which is currently not equipped with trigger chambers, will be instrumented with resistive platechambers (RPCs) in the next long shutdown of the LHC in 2019 and 2020. As the space in this region is extremely limited the present muon drift-tube chambers will have to be removed and replaced by an integrated system of thin-gap RPCs and small diameter muon drift-tube (sMDT) chambers. Final prototypes of both chambers have been successfully produced recently fulfilling all very tight spatial requirements and showing the expected performance. Results of mechanical measurements of the sMDT chamber geometry with a coordinate measurement machine show a wire positioning accuracy of better than $10$ µm. The tests of the thin-gap RPC in a high-energy muon beam at CERN show full chamber efficiency and an unprecedented time resolution better than $0.5$ ns. In the conference contribution the design, construction, and tests of the new sMDT and RPC chambers, as well as the progress of series production, will be presented.
id oai-inspirehep.net-1713196
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2018
publisher SISSA
record_format invenio
spelling oai-inspirehep.net-17131962019-10-15T15:21:43Zdoi:10.22323/1.321.0083http://cds.cern.ch/record/2668904engWalbrecht, Verena MariaPhase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate ChambersDetectors and Experimental TechniquesThe ATLAS muon spectrometer comprises excellent muon trigger capabilities and high muon momentum resolution up to the TeV scale. Yet, in a small region between the barrel and end-cap parts of the muon spectrometer, a non-negligible muon trigger rate from charged particles not emerging from the pp interaction point has been observed.To prevent such fake triggers, the end of the inner ring of the muon spectrometer barrel in the barrel end-cap transition region, which is currently not equipped with trigger chambers, will be instrumented with resistive platechambers (RPCs) in the next long shutdown of the LHC in 2019 and 2020. As the space in this region is extremely limited the present muon drift-tube chambers will have to be removed and replaced by an integrated system of thin-gap RPCs and small diameter muon drift-tube (sMDT) chambers. Final prototypes of both chambers have been successfully produced recently fulfilling all very tight spatial requirements and showing the expected performance. Results of mechanical measurements of the sMDT chamber geometry with a coordinate measurement machine show a wire positioning accuracy of better than $10$ µm. The tests of the thin-gap RPC in a high-energy muon beam at CERN show full chamber efficiency and an unprecedented time resolution better than $0.5$ ns. In the conference contribution the design, construction, and tests of the new sMDT and RPC chambers, as well as the progress of series production, will be presented.SISSAoai:inspirehep.net:17131962018
spellingShingle Detectors and Experimental Techniques
Walbrecht, Verena Maria
Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title_full Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title_fullStr Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title_full_unstemmed Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title_short Phase I and II Upgrades of the ATLAS Muon Spectrometer with Integrated Small Diameter Drift Tube Chambers and Thin-Gap Resistive Plate Chambers
title_sort phase i and ii upgrades of the atlas muon spectrometer with integrated small diameter drift tube chambers and thin-gap resistive plate chambers
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.321.0083
http://cds.cern.ch/record/2668904
work_keys_str_mv AT walbrechtverenamaria phaseiandiiupgradesoftheatlasmuonspectrometerwithintegratedsmalldiameterdrifttubechambersandthingapresistiveplatechambers