Cargando…

BPM Time of Flight Measurements for Setting-up the RF Cavities of the CERN Linac4

The newly constructed H$^-$ LINAC4 at CERN has recently completed its first extended reliability run. It is equipped with Beam Position Monitors (BPMs) based on shorted-stripline pick-up electrodes to measure both position and Time of Flight (ToF). The ToF, in turn used to calculate the kinetic ener...

Descripción completa

Detalles Bibliográficos
Autor principal: Bozzolan, Michele
Lenguaje:eng
Publicado: 2018
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-LINAC2018-THPO084
http://cds.cern.ch/record/2669846
Descripción
Sumario:The newly constructed H$^-$ LINAC4 at CERN has recently completed its first extended reliability run. It is equipped with Beam Position Monitors (BPMs) based on shorted-stripline pick-up electrodes to measure both position and Time of Flight (ToF). The ToF, in turn used to calculate the kinetic energy of the beam, is determined through signal phase shift measurements between pairs of BPMs. ToF measurements are performed by scanning of the phase of the RF injected into the cavities to find the nominal RF settings for optimal beam acceleration. This paper focuses on the technical aspects of the ToF measurement as well as on the results obtained during beam commissioning and their comparison with beam dynamics simulations.