FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy

While Monte Carlo (MC) codes are considered as the gold standard for dosimetric calculations, the availability of user friendly MC codes suited for particle therapy is limited. Based on the FLUKA MC code and its graphical user interface (GUI) Flair, we developed an easy-to-use tool which enables sim...

Descripción completa

Detalles Bibliográficos
Autores principales: Kozłowska, Wioletta Sandra, Böhlen, Till Tobias, Cuccagna, Caterina, Ferrari, Alfredo, Fracchiolla, Francesco, Georg, Dietmar, Magro, Giuseppe, Mairani, Andrea, Schwarz, Marco, Vlachoudis, Vasilis
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1361-6560/ab02cb
http://cds.cern.ch/record/2677774
_version_ 1780962831226634240
author Kozłowska, Wioletta Sandra
Böhlen, Till Tobias
Cuccagna, Caterina
Ferrari, Alfredo
Fracchiolla, Francesco
Georg, Dietmar
Magro, Giuseppe
Mairani, Andrea
Schwarz, Marco
Vlachoudis, Vasilis
author_facet Kozłowska, Wioletta Sandra
Böhlen, Till Tobias
Cuccagna, Caterina
Ferrari, Alfredo
Fracchiolla, Francesco
Georg, Dietmar
Magro, Giuseppe
Mairani, Andrea
Schwarz, Marco
Vlachoudis, Vasilis
author_sort Kozłowska, Wioletta Sandra
collection CERN
description While Monte Carlo (MC) codes are considered as the gold standard for dosimetric calculations, the availability of user friendly MC codes suited for particle therapy is limited. Based on the FLUKA MC code and its graphical user interface (GUI) Flair, we developed an easy-to-use tool which enables simple and reliable simulations for particle therapy. In this paper we provide an overview of functionalities of the tool and with the presented clinical, proton and carbon ion therapy examples we demonstrate its reliability and the usability in the clinical environment and show its flexibility for research purposes. The first, easy-to-use FLUKA MC platform for particle therapy with GUI functionalities allows a user with a minimal effort and reduced knowledge about MC details to apply MC at their facility and is expected to enhance the popularity of the MC for both research and clinical quality assurance and commissioning purposes.
id oai-inspirehep.net-1720150
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17201502022-08-10T12:24:22Zdoi:10.1088/1361-6560/ab02cbhttp://cds.cern.ch/record/2677774engKozłowska, Wioletta SandraBöhlen, Till TobiasCuccagna, CaterinaFerrari, AlfredoFracchiolla, FrancescoGeorg, DietmarMagro, GiuseppeMairani, AndreaSchwarz, MarcoVlachoudis, VasilisFLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapyDetectors and Experimental TechniquesWhile Monte Carlo (MC) codes are considered as the gold standard for dosimetric calculations, the availability of user friendly MC codes suited for particle therapy is limited. Based on the FLUKA MC code and its graphical user interface (GUI) Flair, we developed an easy-to-use tool which enables simple and reliable simulations for particle therapy. In this paper we provide an overview of functionalities of the tool and with the presented clinical, proton and carbon ion therapy examples we demonstrate its reliability and the usability in the clinical environment and show its flexibility for research purposes. The first, easy-to-use FLUKA MC platform for particle therapy with GUI functionalities allows a user with a minimal effort and reduced knowledge about MC details to apply MC at their facility and is expected to enhance the popularity of the MC for both research and clinical quality assurance and commissioning purposes.oai:inspirehep.net:17201502019
spellingShingle Detectors and Experimental Techniques
Kozłowska, Wioletta Sandra
Böhlen, Till Tobias
Cuccagna, Caterina
Ferrari, Alfredo
Fracchiolla, Francesco
Georg, Dietmar
Magro, Giuseppe
Mairani, Andrea
Schwarz, Marco
Vlachoudis, Vasilis
FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title_full FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title_fullStr FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title_full_unstemmed FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title_short FLUKA particle therapy tool for Monte Carlo independent calculation of scanned proton and carbon ion beam therapy
title_sort fluka particle therapy tool for monte carlo independent calculation of scanned proton and carbon ion beam therapy
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1361-6560/ab02cb
http://cds.cern.ch/record/2677774
work_keys_str_mv AT kozłowskawiolettasandra flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT bohlentilltobias flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT cuccagnacaterina flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT ferrarialfredo flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT fracchiollafrancesco flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT georgdietmar flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT magrogiuseppe flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT mairaniandrea flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT schwarzmarco flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy
AT vlachoudisvasilis flukaparticletherapytoolformontecarloindependentcalculationofscannedprotonandcarbonionbeamtherapy