Timing performance study of Multigap Resistive Plate Chamber with different gap size

This paper reports on the results of time resolution measurements of Multigap Resistive Plate Chamber (MRPC). Three 20 gas gaps MRPCs were built with thin float glass sheets and different gap sizes: 160μm , 140μm and 120μm . These chambers have been tested using a different gas flow configurations....

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Z, Carnesecchi, F, Williams, M C S, Zichichi, A, Zuyeuski, R
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2019.02.068
http://cds.cern.ch/record/2686583
_version_ 1780963609293094912
author Liu, Z
Carnesecchi, F
Williams, M C S
Zichichi, A
Zuyeuski, R
author_facet Liu, Z
Carnesecchi, F
Williams, M C S
Zichichi, A
Zuyeuski, R
author_sort Liu, Z
collection CERN
description This paper reports on the results of time resolution measurements of Multigap Resistive Plate Chamber (MRPC). Three 20 gas gaps MRPCs were built with thin float glass sheets and different gap sizes: 160μm , 140μm and 120μm . These chambers have been tested using a different gas flow configurations. The measurements indicate that to reach a better time resolution for small gap size ( 140μm and 120μm ), a smaller gas volume of the chamber is preferable. The efficiency of the chambers in both gas flow configurations has been tested. A time resolution of 25 ps comprehensive of the front-end electronics jitter, with an efficiency of 98% has been achieved for the MRPC with 140μm gas gaps; this is the best time resolution. Moreover, all the chambers have been tested for different particle flux. At the highest particle flux tested, a time resolution better than 60 ps together with an efficiency higher than 80% has been achieved for all the detectors at an instantaneous particle flux of 30  kHz∕cm2 . From the efficiency and time resolution study, the rate capability for these three MRPC is similar.
id oai-inspirehep.net-1724594
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17245942019-11-01T15:05:43Zdoi:10.1016/j.nima.2019.02.068http://cds.cern.ch/record/2686583engLiu, ZCarnesecchi, FWilliams, M C SZichichi, AZuyeuski, RTiming performance study of Multigap Resistive Plate Chamber with different gap sizeDetectors and Experimental TechniquesThis paper reports on the results of time resolution measurements of Multigap Resistive Plate Chamber (MRPC). Three 20 gas gaps MRPCs were built with thin float glass sheets and different gap sizes: 160μm , 140μm and 120μm . These chambers have been tested using a different gas flow configurations. The measurements indicate that to reach a better time resolution for small gap size ( 140μm and 120μm ), a smaller gas volume of the chamber is preferable. The efficiency of the chambers in both gas flow configurations has been tested. A time resolution of 25 ps comprehensive of the front-end electronics jitter, with an efficiency of 98% has been achieved for the MRPC with 140μm gas gaps; this is the best time resolution. Moreover, all the chambers have been tested for different particle flux. At the highest particle flux tested, a time resolution better than 60 ps together with an efficiency higher than 80% has been achieved for all the detectors at an instantaneous particle flux of 30  kHz∕cm2 . From the efficiency and time resolution study, the rate capability for these three MRPC is similar.oai:inspirehep.net:17245942019
spellingShingle Detectors and Experimental Techniques
Liu, Z
Carnesecchi, F
Williams, M C S
Zichichi, A
Zuyeuski, R
Timing performance study of Multigap Resistive Plate Chamber with different gap size
title Timing performance study of Multigap Resistive Plate Chamber with different gap size
title_full Timing performance study of Multigap Resistive Plate Chamber with different gap size
title_fullStr Timing performance study of Multigap Resistive Plate Chamber with different gap size
title_full_unstemmed Timing performance study of Multigap Resistive Plate Chamber with different gap size
title_short Timing performance study of Multigap Resistive Plate Chamber with different gap size
title_sort timing performance study of multigap resistive plate chamber with different gap size
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2019.02.068
http://cds.cern.ch/record/2686583
work_keys_str_mv AT liuz timingperformancestudyofmultigapresistiveplatechamberwithdifferentgapsize
AT carnesecchif timingperformancestudyofmultigapresistiveplatechamberwithdifferentgapsize
AT williamsmcs timingperformancestudyofmultigapresistiveplatechamberwithdifferentgapsize
AT zichichia timingperformancestudyofmultigapresistiveplatechamberwithdifferentgapsize
AT zuyeuskir timingperformancestudyofmultigapresistiveplatechamberwithdifferentgapsize