Induced radioactivity in ATLAS cavern measured by MPX detector network
An application of the use of MPX detectors for the measurement of induced radioactivity in the Large Hadron Collider (LHC) experiment environment is presented. The sixteen ATLAS-MPX detectors measured the associated photon ambient dose equivalent rate (H$^*$(10) rate) in ATLAS due to the LHC operati...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/14/03/P03010 http://cds.cern.ch/record/2686978 |
_version_ | 1780963611483570176 |
---|---|
author | Campbell, M Heijne, E Leroy, C Nessi, M Pospisil, S Solc, J Suk, M Turecek, D Vykydal, Z |
author_facet | Campbell, M Heijne, E Leroy, C Nessi, M Pospisil, S Solc, J Suk, M Turecek, D Vykydal, Z |
author_sort | Campbell, M |
collection | CERN |
description | An application of the use of MPX detectors for the measurement of induced radioactivity in the Large Hadron Collider (LHC) experiment environment is presented. The sixteen ATLAS-MPX detectors measured the associated photon ambient dose equivalent rate (H$^*$(10) rate) in ATLAS due to the LHC operation. It is presented that in 2010 the average H$^*$(10) rate determined with all MPX detectors varies around 0.015 μSv/h in the ATLAS cavern. In 2013, roughly after 50 days from the end of high luminosity physics runs, the highest H$^*$(10) rate measured with the MPX detectors has reached 14.9 μSv/h (in inner detector region). All the other dedicated MPX detectors measured H$^*$(10) rate which reached the value up to 1.3 μSv/h, depending on the MPX detector. |
id | oai-inspirehep.net-1726316 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | oai-inspirehep.net-17263162022-08-10T12:20:05Zdoi:10.1088/1748-0221/14/03/P03010http://cds.cern.ch/record/2686978engCampbell, MHeijne, ELeroy, CNessi, MPospisil, SSolc, JSuk, MTurecek, DVykydal, ZInduced radioactivity in ATLAS cavern measured by MPX detector networkDetectors and Experimental TechniquesAn application of the use of MPX detectors for the measurement of induced radioactivity in the Large Hadron Collider (LHC) experiment environment is presented. The sixteen ATLAS-MPX detectors measured the associated photon ambient dose equivalent rate (H$^*$(10) rate) in ATLAS due to the LHC operation. It is presented that in 2010 the average H$^*$(10) rate determined with all MPX detectors varies around 0.015 μSv/h in the ATLAS cavern. In 2013, roughly after 50 days from the end of high luminosity physics runs, the highest H$^*$(10) rate measured with the MPX detectors has reached 14.9 μSv/h (in inner detector region). All the other dedicated MPX detectors measured H$^*$(10) rate which reached the value up to 1.3 μSv/h, depending on the MPX detector.oai:inspirehep.net:17263162019 |
spellingShingle | Detectors and Experimental Techniques Campbell, M Heijne, E Leroy, C Nessi, M Pospisil, S Solc, J Suk, M Turecek, D Vykydal, Z Induced radioactivity in ATLAS cavern measured by MPX detector network |
title | Induced radioactivity in ATLAS cavern measured by MPX detector network |
title_full | Induced radioactivity in ATLAS cavern measured by MPX detector network |
title_fullStr | Induced radioactivity in ATLAS cavern measured by MPX detector network |
title_full_unstemmed | Induced radioactivity in ATLAS cavern measured by MPX detector network |
title_short | Induced radioactivity in ATLAS cavern measured by MPX detector network |
title_sort | induced radioactivity in atlas cavern measured by mpx detector network |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/14/03/P03010 http://cds.cern.ch/record/2686978 |
work_keys_str_mv | AT campbellm inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT heijnee inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT leroyc inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT nessim inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT pospisils inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT solcj inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT sukm inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT turecekd inducedradioactivityinatlascavernmeasuredbympxdetectornetwork AT vykydalz inducedradioactivityinatlascavernmeasuredbympxdetectornetwork |