Performance of the CMS electromagnetic calorimeter during the LHC Run II

Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. In particular, excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as wel...

Descripción completa

Detalles Bibliográficos
Autor principal: Zghiche, Amina
Lenguaje:eng
Publicado: IOP 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/1162/1/012001
http://cds.cern.ch/record/2715340
_version_ 1780965492712800256
author Zghiche, Amina
author_facet Zghiche, Amina
author_sort Zghiche, Amina
collection CERN
description Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. In particular, excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as well as searches for very high mass resonances decaying to energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to achieve the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to reach and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from $\pi_0$/$\eta$ decays, and from the azimuthally symmetric energy distribution of minimum bias events. This talk presents the new reconstruction algorithm and calibration strategies that were implemented to maintain the excellent performance of the CMS ECAL throughout Run II. Performance results from the Run II data taking period will be reported.
id oai-inspirehep.net-1733043
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
publisher IOP
record_format invenio
spelling oai-inspirehep.net-17330432021-02-09T10:07:23Zdoi:10.1088/1742-6596/1162/1/012001http://cds.cern.ch/record/2715340engZghiche, AminaPerformance of the CMS electromagnetic calorimeter during the LHC Run IIDetectors and Experimental TechniquesParticle Physics - ExperimentMany physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate, high resolution electron and photon energy measurements. In particular, excellent energy resolution is crucial for studies of Higgs boson decays with electromagnetic particles in the final state, as well as searches for very high mass resonances decaying to energetic photons or electrons. Following the excellent performance achieved in Run I at center-of-mass energies of 7 and 8 TeV, the CMS electromagnetic calorimeter (ECAL) is operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy. The instantaneous luminosity delivered by the LHC during Run II has achieved unprecedented values, using 25 ns bunch spacing. High pileup levels necessitate a retuning of the ECAL readout and trigger thresholds and reconstruction algorithms, to achieve the best possible performance in these more challenging conditions. The energy response of the detector must be precisely calibrated and monitored to reach and maintain the excellent performance obtained in Run I in terms of energy scale and resolution. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from $\pi_0$/$\eta$ decays, and from the azimuthally symmetric energy distribution of minimum bias events. This talk presents the new reconstruction algorithm and calibration strategies that were implemented to maintain the excellent performance of the CMS ECAL throughout Run II. Performance results from the Run II data taking period will be reported.IOPoai:inspirehep.net:17330432019
spellingShingle Detectors and Experimental Techniques
Particle Physics - Experiment
Zghiche, Amina
Performance of the CMS electromagnetic calorimeter during the LHC Run II
title Performance of the CMS electromagnetic calorimeter during the LHC Run II
title_full Performance of the CMS electromagnetic calorimeter during the LHC Run II
title_fullStr Performance of the CMS electromagnetic calorimeter during the LHC Run II
title_full_unstemmed Performance of the CMS electromagnetic calorimeter during the LHC Run II
title_short Performance of the CMS electromagnetic calorimeter during the LHC Run II
title_sort performance of the cms electromagnetic calorimeter during the lhc run ii
topic Detectors and Experimental Techniques
Particle Physics - Experiment
url https://dx.doi.org/10.1088/1742-6596/1162/1/012001
http://cds.cern.ch/record/2715340
work_keys_str_mv AT zghicheamina performanceofthecmselectromagneticcalorimeterduringthelhcrunii