Cargando…

Study of a large strip-type MRPC with single-ended readout

A double stack MRPC has been built and equipped with long pickup strips for its readout. It is a double stack design, with each stack having three gas gaps; the gap size is 250 μm. It has a sensitive area of 85 × 85 cm$^2$. Particularly, this MRPC was equipped with readout cards on only one end of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Baek, Y W, Williams, M C S
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2019.06.016
http://cds.cern.ch/record/2689156
_version_ 1780963711552323584
author Baek, Y W
Williams, M C S
author_facet Baek, Y W
Williams, M C S
author_sort Baek, Y W
collection CERN
description A double stack MRPC has been built and equipped with long pickup strips for its readout. It is a double stack design, with each stack having three gas gaps; the gap size is 250 μm. It has a sensitive area of 85 × 85 cm$^2$. Particularly, this MRPC was equipped with readout cards on only one end of the chamber. On the other end, the strips were connected to other strips with 50 Ω coaxial cables. The gas mixture C$_2$F$_4$H$_2$∕SF$_6$ was used during the beam test period.
id oai-inspirehep.net-1741396
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17413962019-09-30T06:29:59Zdoi:10.1016/j.nima.2019.06.016http://cds.cern.ch/record/2689156engBaek, Y WWilliams, M C SStudy of a large strip-type MRPC with single-ended readoutDetectors and Experimental TechniquesA double stack MRPC has been built and equipped with long pickup strips for its readout. It is a double stack design, with each stack having three gas gaps; the gap size is 250 μm. It has a sensitive area of 85 × 85 cm$^2$. Particularly, this MRPC was equipped with readout cards on only one end of the chamber. On the other end, the strips were connected to other strips with 50 Ω coaxial cables. The gas mixture C$_2$F$_4$H$_2$∕SF$_6$ was used during the beam test period.oai:inspirehep.net:17413962019
spellingShingle Detectors and Experimental Techniques
Baek, Y W
Williams, M C S
Study of a large strip-type MRPC with single-ended readout
title Study of a large strip-type MRPC with single-ended readout
title_full Study of a large strip-type MRPC with single-ended readout
title_fullStr Study of a large strip-type MRPC with single-ended readout
title_full_unstemmed Study of a large strip-type MRPC with single-ended readout
title_short Study of a large strip-type MRPC with single-ended readout
title_sort study of a large strip-type mrpc with single-ended readout
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2019.06.016
http://cds.cern.ch/record/2689156
work_keys_str_mv AT baekyw studyofalargestriptypemrpcwithsingleendedreadout