Cargando…

Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade

The steadily increasing luminosity of LHC requires an upgrade to high rate capability and high resolution detector technologies, for the innermost station of the muon spectrometer of the ATLAS experiment. For precision tracking 4 types of 2 and 3 m$^2$ large Micromegas quadruplets will provide 8 con...

Descripción completa

Detalles Bibliográficos
Autores principales: Maniatis, I, Flierl, B, Herrmann, M, Losel, P, Sampsonidis, D
Lenguaje:eng
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2018.11.015
http://cds.cern.ch/record/2717809
_version_ 1780965704559755264
author Maniatis, I
Flierl, B
Herrmann, M
Losel, P
Sampsonidis, D
author_facet Maniatis, I
Flierl, B
Herrmann, M
Losel, P
Sampsonidis, D
author_sort Maniatis, I
collection CERN
description The steadily increasing luminosity of LHC requires an upgrade to high rate capability and high resolution detector technologies, for the innermost station of the muon spectrometer of the ATLAS experiment. For precision tracking 4 types of 2 and 3 m$^2$ large Micromegas quadruplets will provide 8 consecutive active layers, each with 100  μ m spatial resolution per individual plane. Data taken at the 120 GeV SPS muon and pion beam in August 2017 on one 2 m$^2$ quadruplet prototype (SM2 built by the German colleagues). The full active area of the SM2 prototype quadruplet has been calibrated in the Munich Cosmic Ray Facility (CRF).
id oai-inspirehep.net-1741601
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
publisher Elsevier
record_format invenio
spelling oai-inspirehep.net-17416012020-05-14T07:25:22Zdoi:10.1016/j.nima.2018.11.015http://cds.cern.ch/record/2717809engManiatis, IFlierl, BHerrmann, MLosel, PSampsonidis, DPerformance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgradeDetectors and Experimental TechniquesThe steadily increasing luminosity of LHC requires an upgrade to high rate capability and high resolution detector technologies, for the innermost station of the muon spectrometer of the ATLAS experiment. For precision tracking 4 types of 2 and 3 m$^2$ large Micromegas quadruplets will provide 8 consecutive active layers, each with 100  μ m spatial resolution per individual plane. Data taken at the 120 GeV SPS muon and pion beam in August 2017 on one 2 m$^2$ quadruplet prototype (SM2 built by the German colleagues). The full active area of the SM2 prototype quadruplet has been calibrated in the Munich Cosmic Ray Facility (CRF).Elsevieroai:inspirehep.net:17416012019
spellingShingle Detectors and Experimental Techniques
Maniatis, I
Flierl, B
Herrmann, M
Losel, P
Sampsonidis, D
Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title_full Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title_fullStr Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title_full_unstemmed Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title_short Performance and calibration of a 2 m$^2$ SM2 micromegas detector for the ATLAS muon spectrometer upgrade
title_sort performance and calibration of a 2 m$^2$ sm2 micromegas detector for the atlas muon spectrometer upgrade
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2018.11.015
http://cds.cern.ch/record/2717809
work_keys_str_mv AT maniatisi performanceandcalibrationofa2m2sm2micromegasdetectorfortheatlasmuonspectrometerupgrade
AT flierlb performanceandcalibrationofa2m2sm2micromegasdetectorfortheatlasmuonspectrometerupgrade
AT herrmannm performanceandcalibrationofa2m2sm2micromegasdetectorfortheatlasmuonspectrometerupgrade
AT loselp performanceandcalibrationofa2m2sm2micromegasdetectorfortheatlasmuonspectrometerupgrade
AT sampsonidisd performanceandcalibrationofa2m2sm2micromegasdetectorfortheatlasmuonspectrometerupgrade