Cargando…

High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment

For the upgrade of the innermost station of the forward muon spectrometer of the ATLAS experiment large Micromegas (MM) detectors of 2 and 3 m$^2$ with 4 active layers each are foreseen. Four types of MM chambers are produced among four sites. Each sites has to deliver 32 quadruplets or 128 active p...

Descripción completa

Detalles Bibliográficos
Autor principal: Massarotti, P
Lenguaje:eng
Publicado: Elsevier  2019
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2018.09.008
http://cds.cern.ch/record/2717573
_version_ 1780965706117939200
author Massarotti, P
author_facet Massarotti, P
author_sort Massarotti, P
collection CERN
description For the upgrade of the innermost station of the forward muon spectrometer of the ATLAS experiment large Micromegas (MM) detectors of 2 and 3 m$^2$ with 4 active layers each are foreseen. Four types of MM chambers are produced among four sites. Each sites has to deliver 32 quadruplets or 128 active planes. The tiny 120μm distance between the 600 V resistive strip anodes and the ground micro-meshes for these large areas require adequate and well adapted cleaning procedures to guarantee high voltage stability. This is particularly critical for strip shaped surfaces made from resistive material where remnants from the lithographic production processes must be completely removed. The procedure foreseen a visual inspections to be carried on during cleaning and assembly procedures; a wet cleaning procedure to remove dust and possible ionic components of salts from the anode surfaces; a dry cleaning procedure to remove dust; HV tests to be done to validate the cleaning. The cleaning procedure will be illustrated for a New Small Wheel (NSW) Outer Small Module (SM2) of 2 m$^2$.
id oai-inspirehep.net-1741670
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
publisher Elsevier 
record_format invenio
spelling oai-inspirehep.net-17416702022-09-28T13:20:36Zdoi:10.1016/j.nima.2018.09.008http://cds.cern.ch/record/2717573engMassarotti, PHigh voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experimentDetectors and Experimental TechniquesFor the upgrade of the innermost station of the forward muon spectrometer of the ATLAS experiment large Micromegas (MM) detectors of 2 and 3 m$^2$ with 4 active layers each are foreseen. Four types of MM chambers are produced among four sites. Each sites has to deliver 32 quadruplets or 128 active planes. The tiny 120μm distance between the 600 V resistive strip anodes and the ground micro-meshes for these large areas require adequate and well adapted cleaning procedures to guarantee high voltage stability. This is particularly critical for strip shaped surfaces made from resistive material where remnants from the lithographic production processes must be completely removed. The procedure foreseen a visual inspections to be carried on during cleaning and assembly procedures; a wet cleaning procedure to remove dust and possible ionic components of salts from the anode surfaces; a dry cleaning procedure to remove dust; HV tests to be done to validate the cleaning. The cleaning procedure will be illustrated for a New Small Wheel (NSW) Outer Small Module (SM2) of 2 m$^2$.Elsevier oai:inspirehep.net:17416702019
spellingShingle Detectors and Experimental Techniques
Massarotti, P
High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title_full High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title_fullStr High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title_full_unstemmed High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title_short High voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (SM2) for the upgrade of the forward muon spectrometer of the ATLAS experiment
title_sort high voltage stability and cleaning of 2 m$^2$ resistive strip micromegas detectors (sm2) for the upgrade of the forward muon spectrometer of the atlas experiment
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2018.09.008
http://cds.cern.ch/record/2717573
work_keys_str_mv AT massarottip highvoltagestabilityandcleaningof2m2resistivestripmicromegasdetectorssm2fortheupgradeoftheforwardmuonspectrometeroftheatlasexperiment