A quadruple GEM detector has been assembled and operated using Ar/CO$_2$ 90:10 and 70:30 gas mixtures. Detailed study of the effective gain and energy resolution of the detector are performed using the X-ray spectrum of $^{55}$Fe source. The gain and energy resolution of the detector are measured an...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2018.11.019 http://cds.cern.ch/record/2717431 |
_version_ | 1780965707688706048 |
---|---|
author | Patra, Rajendra Nath Singaraju, Rama Narayan Dalal, Somnath Biswas, Saikat Viyogi, Yogendra P Nayak, Tapan K |
author_facet | Patra, Rajendra Nath Singaraju, Rama Narayan Dalal, Somnath Biswas, Saikat Viyogi, Yogendra P Nayak, Tapan K |
author_sort | Patra, Rajendra Nath |
collection | CERN |
description | A quadruple GEM detector has been assembled and operated using Ar/CO$_2$ 90:10 and 70:30 gas mixtures. Detailed study of the effective gain and energy resolution of the detector are performed using the X-ray spectrum of $^{55}$Fe source. The gain and energy resolution of the detector are measured and compared for two different electric field configurations, the standard field setting and the ion backflow ( IBF ) field setting. It is observed that for the standard field configuration the quadruple GEM detector can operate at lower operating voltages and has better energy resolution compared to IBF field setting. |
id | oai-inspirehep.net-1741707 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
publisher | Elsevier |
record_format | invenio |
spelling | oai-inspirehep.net-17417072020-05-11T13:29:13Zdoi:10.1016/j.nima.2018.11.019http://cds.cern.ch/record/2717431engPatra, Rajendra NathSingaraju, Rama NarayanDalal, SomnathBiswas, SaikatViyogi, Yogendra PNayak, Tapan KCharacteristic study of a quadruple GEM detector in different electric field configurationsDetectors and Experimental TechniquesA quadruple GEM detector has been assembled and operated using Ar/CO$_2$ 90:10 and 70:30 gas mixtures. Detailed study of the effective gain and energy resolution of the detector are performed using the X-ray spectrum of $^{55}$Fe source. The gain and energy resolution of the detector are measured and compared for two different electric field configurations, the standard field setting and the ion backflow ( IBF ) field setting. It is observed that for the standard field configuration the quadruple GEM detector can operate at lower operating voltages and has better energy resolution compared to IBF field setting.Elsevieroai:inspirehep.net:17417072019 |
spellingShingle | Detectors and Experimental Techniques Patra, Rajendra Nath Singaraju, Rama Narayan Dalal, Somnath Biswas, Saikat Viyogi, Yogendra P Nayak, Tapan K Characteristic study of a quadruple GEM detector in different electric field configurations |
title | Characteristic study of a quadruple GEM detector in different electric field configurations |
title_full | Characteristic study of a quadruple GEM detector in different electric field configurations |
title_fullStr | Characteristic study of a quadruple GEM detector in different electric field configurations |
title_full_unstemmed | Characteristic study of a quadruple GEM detector in different electric field configurations |
title_short | Characteristic study of a quadruple GEM detector in different electric field configurations |
title_sort | characteristic study of a quadruple gem detector in different electric field configurations |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2018.11.019 http://cds.cern.ch/record/2717431 |
work_keys_str_mv | AT patrarajendranath characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations AT singarajuramanarayan characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations AT dalalsomnath characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations AT biswassaikat characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations AT viyogiyogendrap characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations AT nayaktapank characteristicstudyofaquadruplegemdetectorindifferentelectricfieldconfigurations |