Analysis and simulation of the "after-pulse" RF breakdown
During the high power experiment of a single-cell standing-wave accelerating structure, it was observed that many RF breakdowns happen when the field inside cavity is decaying after the input rf pulse is off. The distribution of breakdown timing shows a peak at the moment of RF power switches off. A...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2019-MOPGW047 http://cds.cern.ch/record/2696263 |
Sumario: | During the high power experiment of a single-cell standing-wave accelerating structure, it was observed that many RF breakdowns happen when the field inside cavity is decaying after the input rf pulse is off. The distribution of breakdown timing shows a peak at the moment of RF power switches off. A series of simulation was performed to study the after-pulse breakdown effect in such a standing-wave structure. A method of calculating poynting vector over time is proposed in this article to study the modified poynting vector at critical points in the cavity. Field simulation and thermal calculation were also carried out to analyse possible reasons for the after-pulse breakdown effect. |
---|