Cargando…

Linear and non-linear optics measurements in PS using turn-by-turn BPM data

For the first time, the optics of the CERN Proton Synchrotron (PS) was measured using turn-by-turn BPM data of forced betatron oscillations excited with an AC dipole. We report results of phase advance and beta-beating measurements. Linear coupling was globally minimised along the machine by measuri...

Descripción completa

Detalles Bibliográficos
Autores principales: Skowroński, Piotr, Giovannozzi, Massimo, Huschauer, Alexander
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.18429/JACoW-IPAC2019-MOPTS102
http://cds.cern.ch/record/2694231
_version_ 1780964087576920064
author Skowroński, Piotr
Giovannozzi, Massimo
Huschauer, Alexander
author_facet Skowroński, Piotr
Giovannozzi, Massimo
Huschauer, Alexander
author_sort Skowroński, Piotr
collection CERN
description For the first time, the optics of the CERN Proton Synchrotron (PS) was measured using turn-by-turn BPM data of forced betatron oscillations excited with an AC dipole. We report results of phase advance and beta-beating measurements. Linear coupling was globally minimised along the machine by measuring and correcting coupling resonance driving terms. Finally, non-linear properties of the ring were probed looking at third- and fourth-order resonance driving terms and amplitude detuning.
id oai-inspirehep.net-1744933
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17449332022-04-05T15:15:01Zdoi:10.18429/JACoW-IPAC2019-MOPTS102http://cds.cern.ch/record/2694231engSkowroński, PiotrGiovannozzi, MassimoHuschauer, AlexanderLinear and non-linear optics measurements in PS using turn-by-turn BPM dataAccelerators and Storage RingsFor the first time, the optics of the CERN Proton Synchrotron (PS) was measured using turn-by-turn BPM data of forced betatron oscillations excited with an AC dipole. We report results of phase advance and beta-beating measurements. Linear coupling was globally minimised along the machine by measuring and correcting coupling resonance driving terms. Finally, non-linear properties of the ring were probed looking at third- and fourth-order resonance driving terms and amplitude detuning.CERN-ACC-2019-176oai:inspirehep.net:17449332019
spellingShingle Accelerators and Storage Rings
Skowroński, Piotr
Giovannozzi, Massimo
Huschauer, Alexander
Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title_full Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title_fullStr Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title_full_unstemmed Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title_short Linear and non-linear optics measurements in PS using turn-by-turn BPM data
title_sort linear and non-linear optics measurements in ps using turn-by-turn bpm data
topic Accelerators and Storage Rings
url https://dx.doi.org/10.18429/JACoW-IPAC2019-MOPTS102
http://cds.cern.ch/record/2694231
work_keys_str_mv AT skowronskipiotr linearandnonlinearopticsmeasurementsinpsusingturnbyturnbpmdata
AT giovannozzimassimo linearandnonlinearopticsmeasurementsinpsusingturnbyturnbpmdata
AT huschaueralexander linearandnonlinearopticsmeasurementsinpsusingturnbyturnbpmdata