Cargando…
Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac
A new RF system is being established at XBOX1 to drive two 100 MV/m CLIC structures in the CLEAR electron linac. In the past, these structures had been powered by RF from PET structures excited by a drive beam. This drive beam is no longer available. The upgrade will reroute power from the 50 MW kly...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.18429/JACoW-IPAC2019-WEPRB063 http://cds.cern.ch/record/2693526 |
_version_ | 1780964013038895104 |
---|---|
author | Edwards, Amelia Catalán Lasheras, Nuria Gonzalez Anton, Sergio McMonagle, Gerard Pitman, Sam Woolley, Benjamin del Pozo Romano, Veronica Dexter, A |
author_facet | Edwards, Amelia Catalán Lasheras, Nuria Gonzalez Anton, Sergio McMonagle, Gerard Pitman, Sam Woolley, Benjamin del Pozo Romano, Veronica Dexter, A |
author_sort | Edwards, Amelia |
collection | CERN |
description | A new RF system is being established at XBOX1 to drive two 100 MV/m CLIC structures in the CLEAR electron linac. In the past, these structures had been powered by RF from PET structures excited by a drive beam. This drive beam is no longer available. The upgrade will reroute power from the 50 MW klystron and pulse compressor which was previously used to power the structure in XBOX1. During the upgrade, the LLRF system will be optimised to improve the modulation of the output signals and down-mixing of the returning signals to obtain accurate phase and amplitude information. The design of the improved LLRF and software, along with phase noise measurements and comparisons with the old system are made in this paper. |
id | oai-inspirehep.net-1745450 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | oai-inspirehep.net-17454502020-09-28T09:53:11Zdoi:10.18429/JACoW-IPAC2019-WEPRB063http://cds.cern.ch/record/2693526engEdwards, AmeliaCatalán Lasheras, NuriaGonzalez Anton, SergioMcMonagle, GerardPitman, SamWoolley, Benjamindel Pozo Romano, VeronicaDexter, AConnection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linacAccelerators and Storage RingsA new RF system is being established at XBOX1 to drive two 100 MV/m CLIC structures in the CLEAR electron linac. In the past, these structures had been powered by RF from PET structures excited by a drive beam. This drive beam is no longer available. The upgrade will reroute power from the 50 MW klystron and pulse compressor which was previously used to power the structure in XBOX1. During the upgrade, the LLRF system will be optimised to improve the modulation of the output signals and down-mixing of the returning signals to obtain accurate phase and amplitude information. The design of the improved LLRF and software, along with phase noise measurements and comparisons with the old system are made in this paper.CERN-ACC-2019-111oai:inspirehep.net:17454502019 |
spellingShingle | Accelerators and Storage Rings Edwards, Amelia Catalán Lasheras, Nuria Gonzalez Anton, Sergio McMonagle, Gerard Pitman, Sam Woolley, Benjamin del Pozo Romano, Veronica Dexter, A Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title | Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title_full | Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title_fullStr | Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title_full_unstemmed | Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title_short | Connection of 12 GHz high power RF from the XBOX 1 high gradient test stand to the CLEAR electron linac |
title_sort | connection of 12 ghz high power rf from the xbox 1 high gradient test stand to the clear electron linac |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.18429/JACoW-IPAC2019-WEPRB063 http://cds.cern.ch/record/2693526 |
work_keys_str_mv | AT edwardsamelia connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT catalanlasherasnuria connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT gonzalezantonsergio connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT mcmonaglegerard connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT pitmansam connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT woolleybenjamin connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT delpozoromanoveronica connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac AT dextera connectionof12ghzhighpowerrffromthexbox1highgradientteststandtotheclearelectronlinac |