Two resistive-strip bulk Micromegas detectors have been installed in the Gamma Irradiation Facility at CERN in 2015. The primary goal was to assess the performance of the detectors after longterm irradiation. This study is particularly relevant in view of the adoption of the Micromegas technology fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Farina, Edoardo, Alvarez Gonzalez, Barbara, Bortfeldt, Jonathan Frederik, Iengo, Paolo, Samarati, Jerome, Sekhniaidze, Givi, Sidiropoulou, Ourania, Wotschack, Joerg
Lenguaje:eng
Publicado: SISSA 2019
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.340.0665
http://cds.cern.ch/record/2702452
Descripción
Sumario:Two resistive-strip bulk Micromegas detectors have been installed in the Gamma Irradiation Facility at CERN in 2015. The primary goal was to assess the performance of the detectors after longterm irradiation. This study is particularly relevant in view of the adoption of the Micromegas technology for future upgrades, as in the ATLAS inner muon system. In this region the expected accumulated charge in 10 years of HL-LHC operation has been estimated to be 0.2 C/cm$^2$. After 3 years of continuous irradiation more than 0.3 C/cm$^2$ have been accumulated, allowing to draw clear conclusions concerning ageing effects on the detectors. During this period, the detector currents have been monitored and the performance of the detectors has been studied by combining the photon background with muon beam available at the facility. In particular, the spatial resolution and detector gain have been studied up to about 70 kHz/cm$^2$.