Cargando…
Demonstration of a cavity-based pulse compression system for pulse shape correction
A compact X-band correction cavity chain (CC) has been successfully designed, fabricated and high power tested for the Compact Linear Collider (CLIC) project. The CC consists of eight spherical cavities and four polarizers, and each spherical cavity has a $Q_0$ of 45 000 and a diameter of 7 cm. The...
Autores principales: | Jiang, Yuliang, Zha, Hao, Wang, Ping, Shi, Jiaru, Chen, Huaibi, Millar, William L, Syratchev, Igor |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1103/PhysRevAccelBeams.22.082001 http://cds.cern.ch/record/2688504 |