Cargando…

Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters

In the context of achieving an efficient radiation monitoring system, while also aiming to increase the flexibility of the measurement system, the integrated digital and analog circuitries of the floating gate dosimeter (FGDOS) have been upgraded. The capability to control autonomously the recharge...

Descripción completa

Detalles Bibliográficos
Autores principales: Brucoli, M, Cesari, J, Danzeca, S, Brugger, M, Masi, A, Pineda, A, Dusseau, L, Wrobel, F
Lenguaje:eng
Publicado: 2019
Acceso en línea:https://dx.doi.org/10.1109/TNS.2019.2895366
http://cds.cern.ch/record/2689001
_version_ 1780963722510991360
author Brucoli, M
Cesari, J
Danzeca, S
Brugger, M
Masi, A
Pineda, A
Dusseau, L
Wrobel, F
author_facet Brucoli, M
Cesari, J
Danzeca, S
Brugger, M
Masi, A
Pineda, A
Dusseau, L
Wrobel, F
author_sort Brucoli, M
collection CERN
description In the context of achieving an efficient radiation monitoring system, while also aiming to increase the flexibility of the measurement system, the integrated digital and analog circuitries of the floating gate dosimeter (FGDOS) have been upgraded. The capability to control autonomously the recharge process and the easy access to the data allows exploiting the FGDOS in both the autonomous and passive mode. The former provides the cumulated dose measurement by a sensor coupled to a digital interface. The latter implies the reading of the dose only after the irradiation time, performing the dose detection by positioning the sensor without any supply. In this paper, the functionality and characterization of the new features of the FGDOS are demonstrated. The resolution, the dose range, and the error introduced on the measurements are discussed in detail by analyzing the results of irradiation experiments. The use of a filtering technique in different radiation environments is discussed, as well as the capability to retain the information after multiple readings and the power consumption for each configuration.
id oai-inspirehep.net-1750222
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17502222021-01-05T20:15:40Zdoi:10.1109/TNS.2019.2895366http://cds.cern.ch/record/2689001engBrucoli, MCesari, JDanzeca, SBrugger, MMasi, APineda, ADusseau, LWrobel, FInvestigation on Passive and Autonomous Mode Operation of Floating Gate DosimetersIn the context of achieving an efficient radiation monitoring system, while also aiming to increase the flexibility of the measurement system, the integrated digital and analog circuitries of the floating gate dosimeter (FGDOS) have been upgraded. The capability to control autonomously the recharge process and the easy access to the data allows exploiting the FGDOS in both the autonomous and passive mode. The former provides the cumulated dose measurement by a sensor coupled to a digital interface. The latter implies the reading of the dose only after the irradiation time, performing the dose detection by positioning the sensor without any supply. In this paper, the functionality and characterization of the new features of the FGDOS are demonstrated. The resolution, the dose range, and the error introduced on the measurements are discussed in detail by analyzing the results of irradiation experiments. The use of a filtering technique in different radiation environments is discussed, as well as the capability to retain the information after multiple readings and the power consumption for each configuration.oai:inspirehep.net:17502222019
spellingShingle Brucoli, M
Cesari, J
Danzeca, S
Brugger, M
Masi, A
Pineda, A
Dusseau, L
Wrobel, F
Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title_full Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title_fullStr Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title_full_unstemmed Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title_short Investigation on Passive and Autonomous Mode Operation of Floating Gate Dosimeters
title_sort investigation on passive and autonomous mode operation of floating gate dosimeters
url https://dx.doi.org/10.1109/TNS.2019.2895366
http://cds.cern.ch/record/2689001
work_keys_str_mv AT brucolim investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT cesarij investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT danzecas investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT bruggerm investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT masia investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT pinedaa investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT dusseaul investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters
AT wrobelf investigationonpassiveandautonomousmodeoperationoffloatinggatedosimeters