Cargando…
Petiroc2A: Characterization and Experimental Results
Petiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have be...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/NSSMIC.2018.8824464 http://cds.cern.ch/record/2694254 |
_version_ | 1780964105286320128 |
---|---|
author | Ahmad, Salleh Fleury, Julien Cizel, Jean-Baptiste de la Taille, Christophe Seguin-Moreau, Natalie Gundacker, Stefan Auffray-Hillemanns, Etiennette |
author_facet | Ahmad, Salleh Fleury, Julien Cizel, Jean-Baptiste de la Taille, Christophe Seguin-Moreau, Natalie Gundacker, Stefan Auffray-Hillemanns, Etiennette |
author_sort | Ahmad, Salleh |
collection | CERN |
description | Petiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have been performed at CERN with various SiPM models from FBK, Hamamatsu and Sensl. Scintillators used for the tests are mostly LSO:Ce,Ca crystals with dimensions ranging from 2 × 2 × 3 mm3up to 3 × 3 × 20 mm3. Petiroc2A yields a single-photon time resolution (SPTR) of 90.7 ps FWHM when tested with FBK NUV 1 × 1 mm2SiPM. Meanwhile, the obtained coincidence time resolution (CTR) values when tested with FBK NUV-HD 4 × 4 mm2SiPM and 2 × 2 × 3 mm3LSO:Ce,Ca are 85.5 ps FWHM when measured externally and 127.3 ps FWHM when measured using the ASIC internal TDC. Using longer scintillators, 3 × 3 × 20 mm3LSO:Ce, Ca and Hamamatsu S13360-3050PE SiPM with negative output, Petiroc2A yields a CTR value of 222.5 ps FWHM when measured with internal TDC. Using the same configuration outputting positive SiPM signal, Petiroc2A measured a nearly similar CTR, 225.3 ps FWHM. Similar setup yields, an energy resolution of 12.9% for 511 keV photon after correction when measured internally by Petiroc2A. |
id | oai-inspirehep.net-1757629 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | oai-inspirehep.net-17576292019-10-22T07:10:54Zdoi:10.1109/NSSMIC.2018.8824464http://cds.cern.ch/record/2694254engAhmad, SallehFleury, JulienCizel, Jean-Baptistede la Taille, ChristopheSeguin-Moreau, NatalieGundacker, StefanAuffray-Hillemanns, EtiennettePetiroc2A: Characterization and Experimental ResultsDetectors and Experimental TechniquesOtherPetiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have been performed at CERN with various SiPM models from FBK, Hamamatsu and Sensl. Scintillators used for the tests are mostly LSO:Ce,Ca crystals with dimensions ranging from 2 × 2 × 3 mm3up to 3 × 3 × 20 mm3. Petiroc2A yields a single-photon time resolution (SPTR) of 90.7 ps FWHM when tested with FBK NUV 1 × 1 mm2SiPM. Meanwhile, the obtained coincidence time resolution (CTR) values when tested with FBK NUV-HD 4 × 4 mm2SiPM and 2 × 2 × 3 mm3LSO:Ce,Ca are 85.5 ps FWHM when measured externally and 127.3 ps FWHM when measured using the ASIC internal TDC. Using longer scintillators, 3 × 3 × 20 mm3LSO:Ce, Ca and Hamamatsu S13360-3050PE SiPM with negative output, Petiroc2A yields a CTR value of 222.5 ps FWHM when measured with internal TDC. Using the same configuration outputting positive SiPM signal, Petiroc2A measured a nearly similar CTR, 225.3 ps FWHM. Similar setup yields, an energy resolution of 12.9% for 511 keV photon after correction when measured internally by Petiroc2A.oai:inspirehep.net:17576292019 |
spellingShingle | Detectors and Experimental Techniques Other Ahmad, Salleh Fleury, Julien Cizel, Jean-Baptiste de la Taille, Christophe Seguin-Moreau, Natalie Gundacker, Stefan Auffray-Hillemanns, Etiennette Petiroc2A: Characterization and Experimental Results |
title | Petiroc2A: Characterization and Experimental Results |
title_full | Petiroc2A: Characterization and Experimental Results |
title_fullStr | Petiroc2A: Characterization and Experimental Results |
title_full_unstemmed | Petiroc2A: Characterization and Experimental Results |
title_short | Petiroc2A: Characterization and Experimental Results |
title_sort | petiroc2a: characterization and experimental results |
topic | Detectors and Experimental Techniques Other |
url | https://dx.doi.org/10.1109/NSSMIC.2018.8824464 http://cds.cern.ch/record/2694254 |
work_keys_str_mv | AT ahmadsalleh petiroc2acharacterizationandexperimentalresults AT fleuryjulien petiroc2acharacterizationandexperimentalresults AT cizeljeanbaptiste petiroc2acharacterizationandexperimentalresults AT delataillechristophe petiroc2acharacterizationandexperimentalresults AT seguinmoreaunatalie petiroc2acharacterizationandexperimentalresults AT gundackerstefan petiroc2acharacterizationandexperimentalresults AT auffrayhillemannsetiennette petiroc2acharacterizationandexperimentalresults |