Petiroc2A: Characterization and Experimental Results

Petiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have be...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahmad, Salleh, Fleury, Julien, Cizel, Jean-Baptiste, de la Taille, Christophe, Seguin-Moreau, Natalie, Gundacker, Stefan, Auffray-Hillemanns, Etiennette
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1109/NSSMIC.2018.8824464
http://cds.cern.ch/record/2694254
_version_ 1780964105286320128
author Ahmad, Salleh
Fleury, Julien
Cizel, Jean-Baptiste
de la Taille, Christophe
Seguin-Moreau, Natalie
Gundacker, Stefan
Auffray-Hillemanns, Etiennette
author_facet Ahmad, Salleh
Fleury, Julien
Cizel, Jean-Baptiste
de la Taille, Christophe
Seguin-Moreau, Natalie
Gundacker, Stefan
Auffray-Hillemanns, Etiennette
author_sort Ahmad, Salleh
collection CERN
description Petiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have been performed at CERN with various SiPM models from FBK, Hamamatsu and Sensl. Scintillators used for the tests are mostly LSO:Ce,Ca crystals with dimensions ranging from 2 × 2 × 3 mm3up to 3 × 3 × 20 mm3. Petiroc2A yields a single-photon time resolution (SPTR) of 90.7 ps FWHM when tested with FBK NUV 1 × 1 mm2SiPM. Meanwhile, the obtained coincidence time resolution (CTR) values when tested with FBK NUV-HD 4 × 4 mm2SiPM and 2 × 2 × 3 mm3LSO:Ce,Ca are 85.5 ps FWHM when measured externally and 127.3 ps FWHM when measured using the ASIC internal TDC. Using longer scintillators, 3 × 3 × 20 mm3LSO:Ce, Ca and Hamamatsu S13360-3050PE SiPM with negative output, Petiroc2A yields a CTR value of 222.5 ps FWHM when measured with internal TDC. Using the same configuration outputting positive SiPM signal, Petiroc2A measured a nearly similar CTR, 225.3 ps FWHM. Similar setup yields, an energy resolution of 12.9% for 511 keV photon after correction when measured internally by Petiroc2A.
id oai-inspirehep.net-1757629
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17576292019-10-22T07:10:54Zdoi:10.1109/NSSMIC.2018.8824464http://cds.cern.ch/record/2694254engAhmad, SallehFleury, JulienCizel, Jean-Baptistede la Taille, ChristopheSeguin-Moreau, NatalieGundacker, StefanAuffray-Hillemanns, EtiennettePetiroc2A: Characterization and Experimental ResultsDetectors and Experimental TechniquesOtherPetiroc2A is a 32-channel SiPM readout ASIC, which has been designed for applications requiring precise timing and energy measurement such as time-of-flight positron emission tomography. In this work, experimental results of Petiroc2A are presented. Time and charge measurements for Petiroc2A have been performed at CERN with various SiPM models from FBK, Hamamatsu and Sensl. Scintillators used for the tests are mostly LSO:Ce,Ca crystals with dimensions ranging from 2 × 2 × 3 mm3up to 3 × 3 × 20 mm3. Petiroc2A yields a single-photon time resolution (SPTR) of 90.7 ps FWHM when tested with FBK NUV 1 × 1 mm2SiPM. Meanwhile, the obtained coincidence time resolution (CTR) values when tested with FBK NUV-HD 4 × 4 mm2SiPM and 2 × 2 × 3 mm3LSO:Ce,Ca are 85.5 ps FWHM when measured externally and 127.3 ps FWHM when measured using the ASIC internal TDC. Using longer scintillators, 3 × 3 × 20 mm3LSO:Ce, Ca and Hamamatsu S13360-3050PE SiPM with negative output, Petiroc2A yields a CTR value of 222.5 ps FWHM when measured with internal TDC. Using the same configuration outputting positive SiPM signal, Petiroc2A measured a nearly similar CTR, 225.3 ps FWHM. Similar setup yields, an energy resolution of 12.9% for 511 keV photon after correction when measured internally by Petiroc2A.oai:inspirehep.net:17576292019
spellingShingle Detectors and Experimental Techniques
Other
Ahmad, Salleh
Fleury, Julien
Cizel, Jean-Baptiste
de la Taille, Christophe
Seguin-Moreau, Natalie
Gundacker, Stefan
Auffray-Hillemanns, Etiennette
Petiroc2A: Characterization and Experimental Results
title Petiroc2A: Characterization and Experimental Results
title_full Petiroc2A: Characterization and Experimental Results
title_fullStr Petiroc2A: Characterization and Experimental Results
title_full_unstemmed Petiroc2A: Characterization and Experimental Results
title_short Petiroc2A: Characterization and Experimental Results
title_sort petiroc2a: characterization and experimental results
topic Detectors and Experimental Techniques
Other
url https://dx.doi.org/10.1109/NSSMIC.2018.8824464
http://cds.cern.ch/record/2694254
work_keys_str_mv AT ahmadsalleh petiroc2acharacterizationandexperimentalresults
AT fleuryjulien petiroc2acharacterizationandexperimentalresults
AT cizeljeanbaptiste petiroc2acharacterizationandexperimentalresults
AT delataillechristophe petiroc2acharacterizationandexperimentalresults
AT seguinmoreaunatalie petiroc2acharacterizationandexperimentalresults
AT gundackerstefan petiroc2acharacterizationandexperimentalresults
AT auffrayhillemannsetiennette petiroc2acharacterizationandexperimentalresults