Cargando…
Electron dosimetry in human skin: a reliability assessment of simulation scenarios
The feasibility and reliability of Geant4-based simulation of human skin irradiation by low energy electrons (up to a few MeV) are reviewed, with emphasis on physics validation and the generation of a dedicated phantom for the simulation of Total Skin Electron Therapy.
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2018
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/NSSMIC.2018.8824344 http://cds.cern.ch/record/2694256 |
_version_ | 1780964105709944832 |
---|---|
author | Basaglia, Tullio Han, Haegin Han, Min Cheol Kim, Chan Hyeong Pia, Maria Grazia |
author_facet | Basaglia, Tullio Han, Haegin Han, Min Cheol Kim, Chan Hyeong Pia, Maria Grazia |
author_sort | Basaglia, Tullio |
collection | CERN |
description | The feasibility and reliability of Geant4-based simulation of human skin irradiation by low energy electrons (up to a few MeV) are reviewed, with emphasis on physics validation and the generation of a dedicated phantom for the simulation of Total Skin Electron Therapy. |
id | oai-inspirehep.net-1757658 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2018 |
record_format | invenio |
spelling | oai-inspirehep.net-17576582021-03-01T10:44:03Zdoi:10.1109/NSSMIC.2018.8824344http://cds.cern.ch/record/2694256engBasaglia, TullioHan, HaeginHan, Min CheolKim, Chan HyeongPia, Maria GraziaElectron dosimetry in human skin: a reliability assessment of simulation scenariosDetectors and Experimental TechniquesThe feasibility and reliability of Geant4-based simulation of human skin irradiation by low energy electrons (up to a few MeV) are reviewed, with emphasis on physics validation and the generation of a dedicated phantom for the simulation of Total Skin Electron Therapy.oai:inspirehep.net:17576582018 |
spellingShingle | Detectors and Experimental Techniques Basaglia, Tullio Han, Haegin Han, Min Cheol Kim, Chan Hyeong Pia, Maria Grazia Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title | Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title_full | Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title_fullStr | Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title_full_unstemmed | Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title_short | Electron dosimetry in human skin: a reliability assessment of simulation scenarios |
title_sort | electron dosimetry in human skin: a reliability assessment of simulation scenarios |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/NSSMIC.2018.8824344 http://cds.cern.ch/record/2694256 |
work_keys_str_mv | AT basagliatullio electrondosimetryinhumanskinareliabilityassessmentofsimulationscenarios AT hanhaegin electrondosimetryinhumanskinareliabilityassessmentofsimulationscenarios AT hanmincheol electrondosimetryinhumanskinareliabilityassessmentofsimulationscenarios AT kimchanhyeong electrondosimetryinhumanskinareliabilityassessmentofsimulationscenarios AT piamariagrazia electrondosimetryinhumanskinareliabilityassessmentofsimulationscenarios |