Cargando…

Resonant slow extraction with constant optics for improved separatrix control at the extraction septum

Losses and component activation are limiting performance factors for slow extraction with high-power applications, and new techniques of loss-reduction, such as bent crystals, require a stable and narrow separatrix angular spread. Conventional tune-sweep slow extraction results in an optics change a...

Descripción completa

Detalles Bibliográficos
Autores principales: Kain, V, Velotti, F M, Fraser, M A, Goddard, B, Prieto, J, Stoel, L S, Pari, M
Lenguaje:eng
Publicado: 2019
Materias:
Acceso en línea:https://dx.doi.org/10.1103/PhysRevAccelBeams.22.101001
http://cds.cern.ch/record/2695252
_version_ 1780964138609016832
author Kain, V
Velotti, F M
Fraser, M A
Goddard, B
Prieto, J
Stoel, L S
Pari, M
author_facet Kain, V
Velotti, F M
Fraser, M A
Goddard, B
Prieto, J
Stoel, L S
Pari, M
author_sort Kain, V
collection CERN
description Losses and component activation are limiting performance factors for slow extraction with high-power applications, and new techniques of loss-reduction, such as bent crystals, require a stable and narrow separatrix angular spread. Conventional tune-sweep slow extraction results in an optics change and an accompanying separatrix rotation through the spill. This can be compensated by a dynamic closed-orbit bump, but requires a high level of complexity for setting up and monitoring. For the Super Proton Synchrotron (SPS), a simpler and powerful new extraction technique has been developed and deployed, providing a mechanism to fix the machine optics and hence separatrix completely through the spill. The technique with the name constant optics slow extraction (COSE) relies on high chromaticity and scaling all machine settings with beam rigidity following the momentum distribution of the beam. In this paper we describe the new COSE concept and its successful operational deployment in the SPS during the 2018 run.
id oai-inspirehep.net-1759311
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17593112022-08-10T12:20:30Zdoi:10.1103/PhysRevAccelBeams.22.101001http://cds.cern.ch/record/2695252engKain, VVelotti, F MFraser, M AGoddard, BPrieto, JStoel, L SPari, MResonant slow extraction with constant optics for improved separatrix control at the extraction septumAccelerators and Storage RingsLosses and component activation are limiting performance factors for slow extraction with high-power applications, and new techniques of loss-reduction, such as bent crystals, require a stable and narrow separatrix angular spread. Conventional tune-sweep slow extraction results in an optics change and an accompanying separatrix rotation through the spill. This can be compensated by a dynamic closed-orbit bump, but requires a high level of complexity for setting up and monitoring. For the Super Proton Synchrotron (SPS), a simpler and powerful new extraction technique has been developed and deployed, providing a mechanism to fix the machine optics and hence separatrix completely through the spill. The technique with the name constant optics slow extraction (COSE) relies on high chromaticity and scaling all machine settings with beam rigidity following the momentum distribution of the beam. In this paper we describe the new COSE concept and its successful operational deployment in the SPS during the 2018 run.oai:inspirehep.net:17593112019
spellingShingle Accelerators and Storage Rings
Kain, V
Velotti, F M
Fraser, M A
Goddard, B
Prieto, J
Stoel, L S
Pari, M
Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title_full Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title_fullStr Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title_full_unstemmed Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title_short Resonant slow extraction with constant optics for improved separatrix control at the extraction septum
title_sort resonant slow extraction with constant optics for improved separatrix control at the extraction septum
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1103/PhysRevAccelBeams.22.101001
http://cds.cern.ch/record/2695252
work_keys_str_mv AT kainv resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT velottifm resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT fraserma resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT goddardb resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT prietoj resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT stoells resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum
AT parim resonantslowextractionwithconstantopticsforimprovedseparatrixcontrolattheextractionseptum