RaDoM2: an improved radon dosimeter

A new dosimeter for radon progeny called RaDoM (Radon Dose Monitor) was recently developed at CERN . RaDoM is an active detector able to directly estimate the effective dose due to the radon progeny. The first version, which used the Timepix hybrid pixel detector, a system of filters and a pump, cor...

Descripción completa

Detalles Bibliográficos
Autores principales: Romano, S, Caresana, M, Curioni, A, Silari, M
Lenguaje:eng
Publicado: 2019
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/14/10/P10019
http://cds.cern.ch/record/2697254
_version_ 1780964225546452992
author Romano, S
Caresana, M
Curioni, A
Silari, M
author_facet Romano, S
Caresana, M
Curioni, A
Silari, M
author_sort Romano, S
collection CERN
description A new dosimeter for radon progeny called RaDoM (Radon Dose Monitor) was recently developed at CERN . RaDoM is an active detector able to directly estimate the effective dose due to the radon progeny. The first version, which used the Timepix hybrid pixel detector, a system of filters and a pump, correctly assessed the effective dose in situations where the environmental conditions are characterized by a standard equilibrium factor, but showed low efficiency for low radon concentrations and in clean air environments. In this improved version, RaDoM2, the Timepix has been replaced by a silicon pin diode. This solution has allowed the optimization of the geometry, the pump flow rate and the associated electronics, improving the performance of RaDoM and substantially reducing its manufacturing costs. This paper describes the RaDoM2, its improved performance compared to RaDoM, the cloud and user interface, tests in a radon chamber and on-the-field measurements.
id oai-inspirehep.net-1760666
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17606662019-11-04T14:18:58Zdoi:10.1088/1748-0221/14/10/P10019http://cds.cern.ch/record/2697254engRomano, SCaresana, MCurioni, ASilari, MRaDoM2: an improved radon dosimeterA new dosimeter for radon progeny called RaDoM (Radon Dose Monitor) was recently developed at CERN . RaDoM is an active detector able to directly estimate the effective dose due to the radon progeny. The first version, which used the Timepix hybrid pixel detector, a system of filters and a pump, correctly assessed the effective dose in situations where the environmental conditions are characterized by a standard equilibrium factor, but showed low efficiency for low radon concentrations and in clean air environments. In this improved version, RaDoM2, the Timepix has been replaced by a silicon pin diode. This solution has allowed the optimization of the geometry, the pump flow rate and the associated electronics, improving the performance of RaDoM and substantially reducing its manufacturing costs. This paper describes the RaDoM2, its improved performance compared to RaDoM, the cloud and user interface, tests in a radon chamber and on-the-field measurements.oai:inspirehep.net:17606662019
spellingShingle Romano, S
Caresana, M
Curioni, A
Silari, M
RaDoM2: an improved radon dosimeter
title RaDoM2: an improved radon dosimeter
title_full RaDoM2: an improved radon dosimeter
title_fullStr RaDoM2: an improved radon dosimeter
title_full_unstemmed RaDoM2: an improved radon dosimeter
title_short RaDoM2: an improved radon dosimeter
title_sort radom2: an improved radon dosimeter
url https://dx.doi.org/10.1088/1748-0221/14/10/P10019
http://cds.cern.ch/record/2697254
work_keys_str_mv AT romanos radom2animprovedradondosimeter
AT caresanam radom2animprovedradondosimeter
AT curionia radom2animprovedradondosimeter
AT silarim radom2animprovedradondosimeter