Cargando…
Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
The search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become part...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2019
|
Acceso en línea: | https://dx.doi.org/10.1117/12.2537832 http://cds.cern.ch/record/2702941 |
_version_ | 1780964718849032192 |
---|---|
author | Chernyshova, Maryna Czarski, Tomasz Kowalska-Strzęciwilk, Ewa Malinowski, Karol Poźniak, Krzysztof T Kasprowicz, Grzegorz Zabołotny, Wojciech M Wojeński, Andrzej Krawczyk, Rafał D Linczuk, Paweł Kolasiński, Piotr Gąska, Michał |
author_facet | Chernyshova, Maryna Czarski, Tomasz Kowalska-Strzęciwilk, Ewa Malinowski, Karol Poźniak, Krzysztof T Kasprowicz, Grzegorz Zabołotny, Wojciech M Wojeński, Andrzej Krawczyk, Rafał D Linczuk, Paweł Kolasiński, Piotr Gąska, Michał |
author_sort | Chernyshova, Maryna |
collection | CERN |
description | The search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become particularly important. Currently, a new X-ray imaging detection technology is required for tokamaks such as ITER. X-ray detectors that are being used in existing equipment may rapidly degrade due to large neutron fluxes characteristic for the tokamak environment. Despite the relatively wide use of semiconductor detectors to record SXR radiation (generally ionizing radiation), gas detectors are promising candidates that are suited much better for use in future fusion reactors given their resistance to neutron radiation. The most promising representative of the new gas detector class is the so called Gas Electron Multiplier (GEM), which is characterized by high amplification factor of the primary charge that is originated from photon absorption. Its main advantages are the compactness of the detector, good temporal and spatial resolutions, the ability to discriminate against photon energy and better neutron resistance compared to existing systems. All this makes such a detection system a potentially better candidate for soft X-ray measurements in the ITER and DEMO reactors. In this work, a new type of detection system based on GEM technology was proposed for soft X-ray measurements in the ITER reactor-oriented research, which is being developed at IPPLM. |
id | oai-inspirehep.net-1767250 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
record_format | invenio |
spelling | oai-inspirehep.net-17672502021-03-01T11:00:38Zdoi:10.1117/12.2537832http://cds.cern.ch/record/2702941engChernyshova, MarynaCzarski, TomaszKowalska-Strzęciwilk, EwaMalinowski, KarolPoźniak, Krzysztof TKasprowicz, GrzegorzZabołotny, Wojciech MWojeński, AndrzejKrawczyk, Rafał DLinczuk, PawełKolasiński, PiotrGąska, MichałDesign and development of soft x-ray diagnostics based on GEM detectors at IPPLMThe search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become particularly important. Currently, a new X-ray imaging detection technology is required for tokamaks such as ITER. X-ray detectors that are being used in existing equipment may rapidly degrade due to large neutron fluxes characteristic for the tokamak environment. Despite the relatively wide use of semiconductor detectors to record SXR radiation (generally ionizing radiation), gas detectors are promising candidates that are suited much better for use in future fusion reactors given their resistance to neutron radiation. The most promising representative of the new gas detector class is the so called Gas Electron Multiplier (GEM), which is characterized by high amplification factor of the primary charge that is originated from photon absorption. Its main advantages are the compactness of the detector, good temporal and spatial resolutions, the ability to discriminate against photon energy and better neutron resistance compared to existing systems. All this makes such a detection system a potentially better candidate for soft X-ray measurements in the ITER and DEMO reactors. In this work, a new type of detection system based on GEM technology was proposed for soft X-ray measurements in the ITER reactor-oriented research, which is being developed at IPPLM.oai:inspirehep.net:17672502019 |
spellingShingle | Chernyshova, Maryna Czarski, Tomasz Kowalska-Strzęciwilk, Ewa Malinowski, Karol Poźniak, Krzysztof T Kasprowicz, Grzegorz Zabołotny, Wojciech M Wojeński, Andrzej Krawczyk, Rafał D Linczuk, Paweł Kolasiński, Piotr Gąska, Michał Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title | Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title_full | Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title_fullStr | Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title_full_unstemmed | Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title_short | Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM |
title_sort | design and development of soft x-ray diagnostics based on gem detectors at ipplm |
url | https://dx.doi.org/10.1117/12.2537832 http://cds.cern.ch/record/2702941 |
work_keys_str_mv | AT chernyshovamaryna designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT czarskitomasz designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT kowalskastrzeciwilkewa designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT malinowskikarol designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT pozniakkrzysztoft designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT kasprowiczgrzegorz designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT zabołotnywojciechm designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT wojenskiandrzej designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT krawczykrafałd designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT linczukpaweł designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT kolasinskipiotr designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm AT gaskamichał designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm |