Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM

The search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become part...

Descripción completa

Detalles Bibliográficos
Autores principales: Chernyshova, Maryna, Czarski, Tomasz, Kowalska-Strzęciwilk, Ewa, Malinowski, Karol, Poźniak, Krzysztof T, Kasprowicz, Grzegorz, Zabołotny, Wojciech M, Wojeński, Andrzej, Krawczyk, Rafał D, Linczuk, Paweł, Kolasiński, Piotr, Gąska, Michał
Lenguaje:eng
Publicado: 2019
Acceso en línea:https://dx.doi.org/10.1117/12.2537832
http://cds.cern.ch/record/2702941
_version_ 1780964718849032192
author Chernyshova, Maryna
Czarski, Tomasz
Kowalska-Strzęciwilk, Ewa
Malinowski, Karol
Poźniak, Krzysztof T
Kasprowicz, Grzegorz
Zabołotny, Wojciech M
Wojeński, Andrzej
Krawczyk, Rafał D
Linczuk, Paweł
Kolasiński, Piotr
Gąska, Michał
author_facet Chernyshova, Maryna
Czarski, Tomasz
Kowalska-Strzęciwilk, Ewa
Malinowski, Karol
Poźniak, Krzysztof T
Kasprowicz, Grzegorz
Zabołotny, Wojciech M
Wojeński, Andrzej
Krawczyk, Rafał D
Linczuk, Paweł
Kolasiński, Piotr
Gąska, Michał
author_sort Chernyshova, Maryna
collection CERN
description The search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become particularly important. Currently, a new X-ray imaging detection technology is required for tokamaks such as ITER. X-ray detectors that are being used in existing equipment may rapidly degrade due to large neutron fluxes characteristic for the tokamak environment. Despite the relatively wide use of semiconductor detectors to record SXR radiation (generally ionizing radiation), gas detectors are promising candidates that are suited much better for use in future fusion reactors given their resistance to neutron radiation. The most promising representative of the new gas detector class is the so called Gas Electron Multiplier (GEM), which is characterized by high amplification factor of the primary charge that is originated from photon absorption. Its main advantages are the compactness of the detector, good temporal and spatial resolutions, the ability to discriminate against photon energy and better neutron resistance compared to existing systems. All this makes such a detection system a potentially better candidate for soft X-ray measurements in the ITER and DEMO reactors. In this work, a new type of detection system based on GEM technology was proposed for soft X-ray measurements in the ITER reactor-oriented research, which is being developed at IPPLM.
id oai-inspirehep.net-1767250
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2019
record_format invenio
spelling oai-inspirehep.net-17672502021-03-01T11:00:38Zdoi:10.1117/12.2537832http://cds.cern.ch/record/2702941engChernyshova, MarynaCzarski, TomaszKowalska-Strzęciwilk, EwaMalinowski, KarolPoźniak, Krzysztof TKasprowicz, GrzegorzZabołotny, Wojciech MWojeński, AndrzejKrawczyk, Rafał DLinczuk, PawełKolasiński, PiotrGąska, MichałDesign and development of soft x-ray diagnostics based on GEM detectors at IPPLMThe search for new technologies in the field of plasma diagnostics entails the increasing demands on the radiative stability of the used materials due to development and usage of fusion facilities, where the study of processes occurring during the interaction of radiation with matter has become particularly important. Currently, a new X-ray imaging detection technology is required for tokamaks such as ITER. X-ray detectors that are being used in existing equipment may rapidly degrade due to large neutron fluxes characteristic for the tokamak environment. Despite the relatively wide use of semiconductor detectors to record SXR radiation (generally ionizing radiation), gas detectors are promising candidates that are suited much better for use in future fusion reactors given their resistance to neutron radiation. The most promising representative of the new gas detector class is the so called Gas Electron Multiplier (GEM), which is characterized by high amplification factor of the primary charge that is originated from photon absorption. Its main advantages are the compactness of the detector, good temporal and spatial resolutions, the ability to discriminate against photon energy and better neutron resistance compared to existing systems. All this makes such a detection system a potentially better candidate for soft X-ray measurements in the ITER and DEMO reactors. In this work, a new type of detection system based on GEM technology was proposed for soft X-ray measurements in the ITER reactor-oriented research, which is being developed at IPPLM.oai:inspirehep.net:17672502019
spellingShingle Chernyshova, Maryna
Czarski, Tomasz
Kowalska-Strzęciwilk, Ewa
Malinowski, Karol
Poźniak, Krzysztof T
Kasprowicz, Grzegorz
Zabołotny, Wojciech M
Wojeński, Andrzej
Krawczyk, Rafał D
Linczuk, Paweł
Kolasiński, Piotr
Gąska, Michał
Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title_full Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title_fullStr Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title_full_unstemmed Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title_short Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM
title_sort design and development of soft x-ray diagnostics based on gem detectors at ipplm
url https://dx.doi.org/10.1117/12.2537832
http://cds.cern.ch/record/2702941
work_keys_str_mv AT chernyshovamaryna designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT czarskitomasz designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT kowalskastrzeciwilkewa designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT malinowskikarol designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT pozniakkrzysztoft designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT kasprowiczgrzegorz designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT zabołotnywojciechm designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT wojenskiandrzej designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT krawczykrafałd designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT linczukpaweł designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT kolasinskipiotr designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm
AT gaskamichał designanddevelopmentofsoftxraydiagnosticsbasedongemdetectorsatipplm