Cargando…
The Tracker Endcap Pixel detector for CMS phase II upgrade
After the high-luminosity upgrade of the LHC (HL-LHC), the instantaneous luminosity will increase to unprecedented values of $5-7 \times10^{34}\,\mathrm{cm^{-2}s^{-1}}$. In order to cope with these conditions the whole CMS silicon tracker detector will be replaced. This presentation describes the Ph...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
SISSA
2019
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.22323/1.350.0061 http://cds.cern.ch/record/2728089 |
_version_ | 1780966447653060608 |
---|---|
author | Del Burgo, Riccardo |
author_facet | Del Burgo, Riccardo |
author_sort | Del Burgo, Riccardo |
collection | CERN |
description | After the high-luminosity upgrade of the LHC (HL-LHC), the instantaneous luminosity will increase to unprecedented values of $5-7 \times10^{34}\,\mathrm{cm^{-2}s^{-1}}$. In order to cope with these conditions the whole CMS silicon tracker detector will be replaced. This presentation describes the Phase-2 upgrade of the inner pixel system. The new inner pixel detector will be composed of three sub-detectors: the barrel detector (TBPX) consisting of four concentric cylindrical layers, the forward detector (TFPX) consisting of eight small disks on each end, and the end-cap detector (TEPX) with four large disks on each end. |
id | oai-inspirehep.net-1769913 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2019 |
publisher | SISSA |
record_format | invenio |
spelling | oai-inspirehep.net-17699132020-08-15T19:05:36Zdoi:10.22323/1.350.0061http://cds.cern.ch/record/2728089engDel Burgo, RiccardoThe Tracker Endcap Pixel detector for CMS phase II upgradeDetectors and Experimental TechniquesAfter the high-luminosity upgrade of the LHC (HL-LHC), the instantaneous luminosity will increase to unprecedented values of $5-7 \times10^{34}\,\mathrm{cm^{-2}s^{-1}}$. In order to cope with these conditions the whole CMS silicon tracker detector will be replaced. This presentation describes the Phase-2 upgrade of the inner pixel system. The new inner pixel detector will be composed of three sub-detectors: the barrel detector (TBPX) consisting of four concentric cylindrical layers, the forward detector (TFPX) consisting of eight small disks on each end, and the end-cap detector (TEPX) with four large disks on each end.SISSAoai:inspirehep.net:17699132019 |
spellingShingle | Detectors and Experimental Techniques Del Burgo, Riccardo The Tracker Endcap Pixel detector for CMS phase II upgrade |
title | The Tracker Endcap Pixel detector for CMS phase II upgrade |
title_full | The Tracker Endcap Pixel detector for CMS phase II upgrade |
title_fullStr | The Tracker Endcap Pixel detector for CMS phase II upgrade |
title_full_unstemmed | The Tracker Endcap Pixel detector for CMS phase II upgrade |
title_short | The Tracker Endcap Pixel detector for CMS phase II upgrade |
title_sort | tracker endcap pixel detector for cms phase ii upgrade |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.22323/1.350.0061 http://cds.cern.ch/record/2728089 |
work_keys_str_mv | AT delburgoriccardo thetrackerendcappixeldetectorforcmsphaseiiupgrade AT delburgoriccardo trackerendcappixeldetectorforcmsphaseiiupgrade |