Cargando…
Measurement of RF characteristics for Superconducting Quarter-wave Resonator
RF characteristics of unloaded quality factor (Q$_{0}$) and accelerating electric field (E$_{acc}$) were measured for superconducting quarter-wave resonator (QWR) in order to verify the performance. For the accurate measurement of RF characteristics, the measurement method of Q$_{0}$ based RF power...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Acceso en línea: | https://dx.doi.org/10.3938/jkps.76.73 http://cds.cern.ch/record/2706955 |
_version_ | 1780964985005932544 |
---|---|
author | Lee, Jongchul Kadi, Yacine Zhang, Pei Ghergherehchi, Mitra Chai, Jong-Seo |
author_facet | Lee, Jongchul Kadi, Yacine Zhang, Pei Ghergherehchi, Mitra Chai, Jong-Seo |
author_sort | Lee, Jongchul |
collection | CERN |
description | RF characteristics of unloaded quality factor (Q$_{0}$) and accelerating electric field (E$_{acc}$) were measured for superconducting quarter-wave resonator (QWR) in order to verify the performance. For the accurate measurement of RF characteristics, the measurement method of Q$_{0}$ based RF power and RF coupling coefficient was used, and the measurement uncertainty was calculated with statistics analysis of systematic error in RF measurement system. The superconducting QWR was designed with a resonant frequency of 101.28 MHz and an accelerating electric field (E$_{acc}$) of 6 MV/m at a cavity dissipation power of 10 W in the high-intensity and energy isotope separator online device (HIE-ISOLDE) project at CERN. Q-slopes and RF coupling coefficients were measured for three QWRs at the resonant frequency 101.28 MHz. Q$_{0}$ values of QWRs were measured 4.55 × 10$^{8}$, 3.78 × 10$^{8}$ and 3.17 × 10$^{8}$ at the 6 MV/m, respectively, and the measurement uncertainty of Q$_{0}$ and E$_{acc}$ were calculated 2.92% and 3.32%. Performances of superconducting QWRs were acceptable to operate the beam acceleration with consideration of cryomodule capacity in HIEISOLDE project. |
id | oai-inspirehep.net-1775426 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2020 |
record_format | invenio |
spelling | oai-inspirehep.net-17754262021-03-01T11:00:30Zdoi:10.3938/jkps.76.73http://cds.cern.ch/record/2706955engLee, JongchulKadi, YacineZhang, PeiGhergherehchi, MitraChai, Jong-SeoMeasurement of RF characteristics for Superconducting Quarter-wave ResonatorRF characteristics of unloaded quality factor (Q$_{0}$) and accelerating electric field (E$_{acc}$) were measured for superconducting quarter-wave resonator (QWR) in order to verify the performance. For the accurate measurement of RF characteristics, the measurement method of Q$_{0}$ based RF power and RF coupling coefficient was used, and the measurement uncertainty was calculated with statistics analysis of systematic error in RF measurement system. The superconducting QWR was designed with a resonant frequency of 101.28 MHz and an accelerating electric field (E$_{acc}$) of 6 MV/m at a cavity dissipation power of 10 W in the high-intensity and energy isotope separator online device (HIE-ISOLDE) project at CERN. Q-slopes and RF coupling coefficients were measured for three QWRs at the resonant frequency 101.28 MHz. Q$_{0}$ values of QWRs were measured 4.55 × 10$^{8}$, 3.78 × 10$^{8}$ and 3.17 × 10$^{8}$ at the 6 MV/m, respectively, and the measurement uncertainty of Q$_{0}$ and E$_{acc}$ were calculated 2.92% and 3.32%. Performances of superconducting QWRs were acceptable to operate the beam acceleration with consideration of cryomodule capacity in HIEISOLDE project.oai:inspirehep.net:17754262020 |
spellingShingle | Lee, Jongchul Kadi, Yacine Zhang, Pei Ghergherehchi, Mitra Chai, Jong-Seo Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title | Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title_full | Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title_fullStr | Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title_full_unstemmed | Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title_short | Measurement of RF characteristics for Superconducting Quarter-wave Resonator |
title_sort | measurement of rf characteristics for superconducting quarter-wave resonator |
url | https://dx.doi.org/10.3938/jkps.76.73 http://cds.cern.ch/record/2706955 |
work_keys_str_mv | AT leejongchul measurementofrfcharacteristicsforsuperconductingquarterwaveresonator AT kadiyacine measurementofrfcharacteristicsforsuperconductingquarterwaveresonator AT zhangpei measurementofrfcharacteristicsforsuperconductingquarterwaveresonator AT ghergherehchimitra measurementofrfcharacteristicsforsuperconductingquarterwaveresonator AT chaijongseo measurementofrfcharacteristicsforsuperconductingquarterwaveresonator |