Cargando…
Novel low resistivity glass: MRPC detectors for ultra high rate applications
Multigap Resistive Plate Chambers (MRPCs) are often used as time-of-flight (TOF) detectors for high-energy physics and nuclear experiments thanks to their excellent time accuracy. For the Compressed Baryonic Matter (CBM) TOF system, MRPCs are required to work at particle fluxes on the order of 1–10...
Autores principales: | Liu, Z, Beyer, R, Dreyer, J, Fan, X, Greifenhagen, R, Kim, D W, Kotte, R, Garcia, A Laso, Naumann, L, Römer, K, Stach, D, Estrada, C Uribe, Williams, M C S, Zichichi, A |
---|---|
Lenguaje: | eng |
Publicado: |
2020
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2020.163483 http://cds.cern.ch/record/2711396 |
Ejemplares similares
-
Study of the counting rate capability of MRPC detectors built with soda lime glass
por: Forster, R, et al.
Publicado: (2016) -
The MRPC detector for the ALICE Time Of Flight System: Final Design and Perfomances
por: Akindinov, A, et al.
Publicado: (2006) -
The SHiP timing detector based on MRPC
por: Blanco, A, et al.
Publicado: (2020) -
Results from a large sample of MRPC-strip prototypes for ALICE TOF detector
por: Akindinov, A, et al.
Publicado: (2004) -
Proposal for an MRPC system with high-precision timing in the LVD structure
por: Zichichi, A
Publicado: (2012)